Ver 1.4 2001. 01
• MO Automatic Adjustment item
Mode No.
Description
112
113
MO electrical offset adjustment
114
118
221
Lower reflection CD tracking error gain adjustment
223
Lower reflection CD tracking error offset adjustment
232
236
Lower reflection CD ABCD level adjustment
244
Lower reflection CD focus gain adjustment
245
Lower reflection CD tracking gain adjustment
121
MO tracking error gain adjustment
122
MO tracking error offset adjustment
134
MO TWPP gain adjustment
131
MO double speed read TWPP offset adjustment
132
136
MO ABCD level adjustment
144
MO focus gain adjustment
145
MO tracking gain adjustment
138
MO RF gain adjustment
434
MO write TWPP gain adjustment
431
MO write TWPP offset adjustment
432
436
MO write ABCD level adjustment
445
MO write tracking gain adjustment
411
MO normal speed read TWPP offset adjustment
412
448
32 cluster full recording
141
MO focus bias adjustment
10. If the result of automatic adjustment is OK, the following dis-
play appears in the LCD:
LCD display
M O O K
141
11. If the result of automatic adjustment is NG, the following dis-
play appears in the LCD:
LCD display
# # # N G
###: Overall adjustment. NG mode number
12. If NG, set the manual mode. Perform automatic adjustment
for the items not accepted. (See page 12)
13. To clear the data in overall adjustment mode, set the manual
mode and change the mode number 021 (Res NV) to reset the
NV. (See page 12)
14. When both CD and MO overall adjustments are OK, set the
manual mode and clear the clock data.
For the microprocessor version 1.20 or later, set the mode num-
ber 043 (Resume), and press the X key.
LCD display
R e s u m e
043
r Press the X key, historical data clear
R e s C l r
043
Note: In step 10, set the clock data to 99Y11M11D11H11M00S,
and in step 14, do not set the clock.
– 21 –
[Laser Power Check]
Connection :
laser
power meter
Optical pick-up
objective lens
digital voltmeter
MAIN board
Both ends of R1005
Check Method :
1. Select the manual mode of test mode, and set the laser power
adjusting mode. (mode number 010)
2. Press the
.
key continuously until the optical pick-up
moves to the most inward track.
3. Open the cover and set the laser power meter on the objective
lens of the optical pick-up.
4. Press the
key, and set the laser MO read adjustment mode.
N
(mode number 011)
5. Check that the laser power meter reading is 0.81 ± 0.08 mW.
6. Check that the voltage both ends of resitor R1005 at this time
is below 44 mV.
7. Press the
N
key, and set the laser CD read adjustment
mode. (mode number 012)
8. Check that the laser power meter reading is 0.97 ± 0.10 mW.
9. Check that the voltage both ends of resitor R1005 at this time
is below 44 mV.
10. Press the
N
key, and set the laser MO write adjustment mode.
(mode number 013)
11. Check that the laser power meter reading is 4.95 ± 0.50 mW.
12. Check that the voltage both ends of resister R1005 at this time
is below 80 mV.
13. Press the
x
key.
14. Release the test mode.
Connecting Location:
– MAIN BOARD (Component Side) –
TP914
(VR)
TP915
(VC)
TP5105
(GND)
– MAIN BOARD (Conductor Side) –
R1005
(+)
(–)