Flashing fault symbol Cont.
If the water tray jambs during the initial swing
Check the ice tray. If the hinges are trapped under the water tray fig. 1
causing the problem.
Fig. 1
Fig. 2
Fix: Push the bottom of the tray back and slide the tray forward to
release it then check both sides of the water tray in the fully retracted
position fig. 2. The top edge for the tray should not be contacting the
cooling tubes or mount. If it is, gently move the mount out of the path of
the tray. This will stop the tray from twisting and correct the problem.
Water tray stalling but not caught on ice tray.
This is generally caused by a bad drive motor"DIM15.39", broken
tray"DIM15.13" fig.3 or by broken tray hinge "DIM15.15", or position
switches"DIM15.27" fig. 4.
Fig. 3
Fig. 4
Fix; Remove right and left side panels and release motor. Inspect for
physical damage and continuity of the motor windings and switch
contacts.
Replace broken or defective components as needed.