Honeywell X-618 Installation Manual

Public address and voice alarm system
Hide thumbs Also See for X-618:

Advertisement

X-618 Public Address and Voice

Alarm System

Installation Manual
M_XXXXXX_EN_1.0

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell X-618

  • Page 1: Alarm System

    X-618 Public Address and Voice Alarm System Installation Manual M_XXXXXX_EN_1.0...
  • Page 3 The contents of this document are subject to revision without notice due to continued progress in methodology, design, and manufacturing. Honeywell shall have no liability for any error or damage of any kind resulting from the use of this document.
  • Page 4: Safety Guidelines

    Safety Guidelines Danger This sign reminds users of “dangerous voltage” on the product. Caution This sign reminds users of important instructions attached to the product. In order to prevent electric shock, this equipment plug shall not be used as conductor to extend power supply line. Safety guideline Do not block the equipment’s ventilation opening or put other equipment on it.
  • Page 5: Label And User's Manual

    humidity <95%. If the equipment is in operation for a long time and ambient temperature is too high, it is recommended that effective measures should be taken to reduce temperature.  Requirements on grid power supply voltage by the equipment: AC 220V (-15% to +10%) 50- 60Hz.
  • Page 6: Table Of Contents

    Connecting the Protective Grounding Cabinet Wires ............... 8 Installing the DCS and DA in the Appliance Cabinet ................ 9 Connecting the Protective Grounding Appliance Wires..............10 Connecting the X-618 System Components...................10 Connecting the Sound Source Equipment to the DCS.............11 Connecting the DCS to the DA ....................11 Connecting the Dry Contacts (Optional) ...................14...
  • Page 7: Preface

    Describes inspecting the installation of the X-618 Public Address and Voice Alarm System and system commissioning Intended Audience This manual is mainly for personnel who are to install, operate, and maintain the X-618 Broadcasting and Voice Alarm System. Relevant Documents The following documents can be used as a reference when reading this manual: ...
  • Page 8  The Life Safety A/V (Guangzhou) Co., Ltd is not liable for any consequences caused by user mistakes when using the product or user misunderstandings of the manual content.
  • Page 9: System Overview

    The X-NPMI Programmable Network Paging Console is hereinafter referred to as the “NPM” or “X-NPMI”. The NPM is used to page zones and control broadcasts for the X-618 on an Ethernet network. Figure 1 shows the schematic diagram of the X-618 system structure.
  • Page 10: Preparation For Installation

    Gathering Information Installation personnel are required to be familiar with functional components of the X-618 product equipment. It is recommended to first read the product information found in the X-618 Public Address and Voice Alarm System Product Description. Preparing Tools Prepare the following tools before installing the system equipment: ...
  • Page 11: Preparing Auxiliary Materials

     Wire stripping pliers  Wire cutting pliers  RJ45 crimp tool  Slotted screwdriver (M2)  Phillips screwdriver (P1) Preparing Auxiliary Materials Prepare the following auxiliary materials before installing the system equipment:  Insulating tape  Wire buckles  Cable labels ...
  • Page 12 This cable is used to connect the DCS to the DA as well as the DCS to the loudspeakers in the broadcasting zones. Shielded cables with a cross-section of 1.3mm (wire gauge of 16AWG) are recommended to connect the external sound source devices, such as CD/DVD players and tuners.
  • Page 13: Packing List Inspection

    Installing the DCS and DA in the Appliance Cabinet  Connecting the Protective Grounding  Connecting the X-618 System Components  Connecting the Power Supply Note: The electricity and power sources must be turned off when performing the following tasks to avoid electric shocks and damage to the equipment.
  • Page 14: Connecting The Protective Grounding Cabinet Wires

    Figure 2 Schematic Diagram of Creating a Slot for Seating the NPM (Level Surface) Figure 3 Schematic Diagram of Creating a Slot for Seating the NPM(Slanted Surface) Adequate space for wires connecting to the NPM must be reserved on the rear side of the unit. If the surface thickness is greater than 10mm, the space reserved for the wires must be about 80mm long and 10mm wide, as shown in Figure 4.
  • Page 15: Installing The Dcs And Da In The Appliance Cabinet

    Figure 6 Schematic Diagram of Cabinet Grounding Installing the DCS and DA in the Appliance Cabinet Install the DCS and DA into the associated appliance cabinet. This process is described in the following steps: Connect and hang the emergency microphone in place on the front panel of the DCS. An installed emergency microphone is shown in Figure 7.
  • Page 16: Connecting The Protective Grounding Appliance Wires

    Do not connect the grounding output cable with the grounding input cable as a short circuit can occur. Connecting the X-618 System Components This section describes the connections between the following X-618 system components:  Connecting the Sound Source Equipment to the DCS...
  • Page 17: Connecting The Sound Source Equipment To The Dcs

     Connecting the DCS to the DA  Connecting the DCS to the NPM  Connecting the Dry Contacts (Optional)  Connecting the Dry Contacts (Optional)  Connecting the Noise Detector (Optional) Connecting the Sound Source Equipment to the DCS Connect the external sound source equipment to the DCS appliance as necessary.
  • Page 18 Connecting the DA audio output to the DCS Strip one end of the prepared audio output cable jacket by 10mm, and feed the cable through the DCS protective cover of the terminal, as shown in Figure 12. Figure 12 Schematic Diagram of a Feeding the Audio Output Cable Through the Protective Terminal Cover Take the end of the cable that was fed through the protective cover of the DCS wiring...
  • Page 19 Figure 14 Schematic Diagram of the Audio Output Wiring Terminal Installation Insert the power amplifier input wiring terminal of the installed audio output cable into the DCS PA audio input port, as shown in Figure 15. Figure 15 Schematic Diagram of the Audio Input Wiring Terminal Installation Cover the power amplifier terminal with the protective terminal cover and tighten the screws, as shown in Figure 16.
  • Page 20: Connecting The Dry Contacts (Optional)

    Figure 16 Schematic Diagram of the Protective Audio Input Terminal Cover Connecting the Dry Contacts (Optional) This section describes connecting the external equipment or switch through the dry contacts. Dry Contact Input Preparation Connect the dry contact cable to the dry contact input terminal. Strip the wire jacket off one end of the prepared dry contact connection cable by about 10mm, insert the wires into the dry contact wiring terminal (8P green phoenix tail seating 3.81mm), and tighten the screws.
  • Page 21: Connecting The Noise Detector (Optional)

    Dry Contact Output Preparation Strip off the wire jacket of one end of prepared dry contact output cable by about 10mm, insert dry contact wiring terminal (8P green phoenix tail seating 3.81mm), and tighten the screws. Refer to Figure 13. Insert the dry contact output wiring terminal of the installed output cable into the DCS dry contact port.
  • Page 22: Connecting The Loudspeakers

    Figure 20 Schematic Diagram of the Noise Detector Connection Connecting the Loudspeakers The DCS can be directly connected to loudspeakers. The following steps describe this process: Strip off the wire jacket of one end of the prepared audio cable by about 10mm, insert the loudspeaker wiring terminal, and tighten the screws.
  • Page 23: Connecting The Power Supply Cables

    Figure 23 Schematic Diagram of Connecting the DCS to the NPM Through a Network Switch Connecting the Power Supply Cables The power supply cables for the main X-618 system components include the following items:  DCS Main and Standby Power Supply Cables ...
  • Page 24: Dcs Main And Standby Power Supply Cables

    DCS Main and Standby Power Supply Cables Connecting the Main Power Supply Cable Strip off the wire jacket of one end of the AC power supply cable by 20mm and connect the cable to the main power supply wiring terminal, as shown in Figure 24. Figure 24 Schematic Diagram of the DCS Main Power Supply Cable Connection Note: The wires are identified as L (live wire), N (null wire), and E (grounding wire).
  • Page 25: Da Main And Standby Power Supply Cables

    Figure 25 Schematic Diagram of the DCS Standby Power Supply Cable Connection DA Main and Standby Power Supply Cables Connecting the Main Power Supply Cable Strip off the wire jacket of one end of the AC power supply cable by 20mm and connect the cable to the main power supply wiring terminal, as shown in Figure 24.
  • Page 26: Installation Inspection

    Inspection Inspect the following items after installing the X-618 system and before turning the system on:  Check if sufficient heat ventilation space is left above the DA appliance.
  • Page 27 www.honeywellav.com Life Safety A/V (Guangzhou) Co., Ltd Address: No. 257 Junye Road, Guangzhou GETDD East 510530, China Tel: +86 (0)20 2839 9600 Fax: +86 (0)20 2820 8706 © 2012 Life Safety A/V (Guangzhou) Co., Ltd. All rights reserved.

Table of Contents