X-618 Public Address and Voice
Alarm System
Installation Manual
M_2000061032_EN_3.2
M_2000061032_EN_3.1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell X-618

  • Page 1 X-618 Public Address and Voice Alarm System Installation Manual M_2000061032_EN_3.2 M_2000061032_EN_3.1...
  • Page 2 The contents of this document are subject to revision without notice due to continued progress in methodology, design, and manufacturing. Honeywell shall have no liability for any error or damage of any kind resulting from the use of this document.
  • Page 3: Safety Guidelines

    Safety Guidelines Danger This sign reminds users of “dangerous voltage” on the product. Caution This sign reminds users of important instructions attached to the product. In order to prevent electric shock, this equipment plug shall not be used as conductor to extend power supply line. Safety guideline Do not block the equipment’s ventilation opening or put other equipment on it.
  • Page 4: Safe Use Precautions

     As the product is not waterproof, do not expose it to rainwater or liquid environment so as to avoid damaging it.  Put the equipment on solid level plane or install it on a rack.  Do not put other articles on the equipment top. Safe Use Precautions ...
  • Page 5: Table Of Contents

    Install the DCS, NRI and DA into the Appliance Cabinet ..............8 Installing the X-NPMS in a Cabinet (Optional) ..................9 Connecting the X-618 System Components ....................10 Connecting the Sound Source Equipment to the DCS or NRI ............10 Connecting the DCS to the DA ......................
  • Page 6: Preface

    Describes inspecting the installation of the X-618 Public Address and Voice Alarm System and system commissioning Intended Reader This manual is mainly for personnel who are to install, operate, and maintain the X-618 Broadcasting and Voice Alarm System. Relevant Documents The following documents can be used as a reference when reading this manual: ...
  • Page 7: System Overview

    X-DA1500/DA2250/DA4125/DA4060 High Efficiency Power Amplifier The X-DA1500/DA2250/DA4125/DA4060 High Efficiency Power Amplifier is hereinafter referred to as the “DA” or “X-DA1500/DA2250/DA4125/DA4060”. In the X-618 system, the DA is used to amplify audio signal power and drive many broadcasting loudspeakers.  X-NPMI Configurable Network Paging Console The X-NPMI Programmable Network Paging Console is used to page zones and control broadcasts for the X-618 on an Ethernet network.
  • Page 8 Figure 1 Connection Schematic Diagram of DCS and X-DA1500 Figure 2 Connection Schematic Diagram of DCS and X-DA2250...
  • Page 9 Figure 3 Connection Schematic Diagram of DCS and X-DA4125/X-DA4060...
  • Page 10: Preparation For Installation

    Gathering Information Installation personnel are required to be familiar with functional components of the X-618 product equipment. It is recommended to first read the product information found in the X-618 Public Address and Voice Alarm System Product Description. Preparing Tools Prepare the following tools before installing the system equipment: ...
  • Page 11 Prepare the following cables and auxiliary equipments before installing the system equipment:  CAT-5 Ethernet cable Cables are required to be no longer than 100m with diameters of 0.51mm (wire gauge of 24AWG). Shielded twisted pair cables are recommended. If the distance between devices is less than 30 meter, the cable can be straight through or cross.
  • Page 12: Packing List Inspection

    Type Legend GND(0V) VCC(12V-24V, powered by an external device) Self-test port  When the DA output voltage is VCC (12V-24V), the DA is being self-tested.  When the DA has no input voltage, the DA is working normally.  Power amplifier output cables Unshielded cables with a cross-section of 1.3mm (wire gauge of 16AWG) are recommended for the power amplifier output.
  • Page 13: System Installation

    Installation Requirements of Cabinet Generally, X-618 system needs to be installed in standard 19’ cabinet for use. Grounding wire inside the cabinet should be well connected to keep system work normally. There are specialized earth wires at the door and the bottom of cabinet.
  • Page 14: Installing The Devices In The Appliance Cabinet

    The bottom plate is also need to install, and the rest space can be filled with blind disk. Spare list of X-618 includes foot, which is used for desktop installation. Make sure there is no foot at the bottom of device before installation.
  • Page 15: Installing The X-Npms In A Cabinet (Optional)

    Put the DCS into the cabinet and fasten it with screws. Figure 6 Schematic Diagram of the DCS Bracket Installation Install the side brackets of X-NRI and follow above steps to install in cabinet. Install the side brackets of DA and follow above steps to install in cabinet. 5.
  • Page 16: Connecting The X-618 System Components

    Connect the external sound source equipment to the DCS or NRI appliance as necessary. The sound source connected to the DCS will be used for broadcasting in this device zones .The sound source connected to the NRI will be used for broadcasting in the all zones of the X-618 system.
  • Page 17: Connecting The Dcs To The Da

    Figure 8 Diagram of DCS Connecting to the Sound Source Equipment X-NRI Connecting the Sound Source Equipment There are 4 auxiliary audio source input interfaces (RCA ports) and 4 balance input interfaces for X-NRI. Auxiliary audio source input interfaces can connect external audio devices directly. The operation is the same as operation on DCS.
  • Page 18 Figure 9 Connection Diagram of Amplifier and Control Port of DCS Connecting the DA audio output to the DCS Strip one end of the prepared audio output cable jacket by 10mm, and feed the cable through the protective cover of the power amplifier. Figure 10 Schematic Diagram of a Feeding the Audio Output Cable through the Protective Terminal Cover Take the end of the cable that was fed through the protective cover of the power amplifier...
  • Page 19 Insert the power amplifier audio output wiring terminal of the installed audio output cable into the DA audio output port. Figure 12 Schematic Diagram of the Audio Output Wiring Terminal Installation Insert the power amplifier input wiring terminal of the installed audio output cable into the DCS PA audio input port.
  • Page 20: Connecting The Dry Contacts (Optional)

    Figure 14 Schematic Diagram of the Protective Audio Input Terminal Cover The way that connects to standby amplifier is similar with the one to main amplifier. Control interfaces of standby amplifier should connect to standby ports of DCS. If use the “single standby amplifier”...
  • Page 21 Figure 16 Schematic Diagram of Dry Contact Input Connecting to Resistance The detailed setting of the fire alarm relation that is triggered through NRI dry contact input, please refer to X-618 Public Address and Voice Alarm System Configuration Manual. DCS Dry Contact Output Preparation Strip off the wire jacket of one end of prepared dry contact output cable by about 10mm, insert dry contact wiring terminal (8P green phoenix tail seating 3.81mm), and tighten the screws.
  • Page 22 Figure 18 Schematic Diagram of the DCS and Four-Line Volume controller Connection NRI Dry Contact Output Preparation The dry contact output of NRI can be configured as fault signal output which will be connected with fire alarm system, and delivery the system fault status. The NO and COM of a dry contact output will be used.
  • Page 23: Connecting The Noise Detector (Optional)

    Connecting the Noise Detector (Optional) If detecting the environmental noise is required, the noise detector can be connected through the AVC port. Connecting the Noise Detector X-ND100 X-DCS2000/X-DCS3000 can only connect to the noise detector X-ND100. Shielded twisted pair cables are used to supply power as well as transfer noise data signal. The steps are as follows: Open the rear cover of noise detector, and set the module address 1~5 according to binary system.
  • Page 24: Connecting The Loudspeakers

    Figure 20 Schematic Diagram of the X-DCS3000 Connecting to Noise Detector Connection Note: Each DCL bus can be connected with up to 5 digital noise detectors. Connecting the Loudspeakers The DCS can be directly connected to loudspeakers. The following steps describe this process: Strip off the wire jacket of one end of the prepared audio cable by about 10mm, insert the loudspeaker wiring terminal, and tighten the screws.
  • Page 25: Connecting The Dcs And Nri To The Npm

    Connecting the DCS and NRI to the NPM In X-618 system, DCS, NRI and NPM form a complete system through the Ethernet. The DCS and NRI can be connected to the NPM in the following two ways:  Directly connecting the DCS and NRI to the NPM ...
  • Page 26 Caution! When install the power cables to the socket, please pay special attention to make sure the polarity of cables should comply with the port of device. The wires are identified as L (Live wire), N (Null wire), and E (Earth wire), or connecting the AC main and standby power will cause a short circuit. Tighten the screws to prevent the power supply cable from coming loose, and cover the power supply interface set.
  • Page 27: Connecting Da Main And Standby Power Supply Cables

    Figure 24 Schematic Diagram of the NRI Standby Power Supply Cable Connection Connecting DA Main and Standby Power Supply Cables Connecting the Main Power Supply Cable Strip off the wire jacket of one end of the prepared standby power supply cable by 20mm and connect the cable to the main power supply wiring terminal.
  • Page 28: Connection To Fire Alarm Control Panel

    POE switcher, which support IEEE802.3 to satisfy the power supply needs. Connection to Fire Alarm Control Panel X-618 system can be connected with fire alarm control panel by dry contact or LPI-Modbus. Dry contact is used for third party FAS without any protocol, LPI-ModBus is only used for Notifier’s fire alarm control panel.
  • Page 29: Connecting Dcs With Fire Alarm Control Panel Through Lpi-Modbus

    NFS2-3030 Connecting DCS with Fire Alarm Control Panel through LPI-ModBus LPI-ModBus(Loop Peripherals Interface) is a SLC-ModBus converter. X-618 is compatible with the V2.0 and V3.0 version of the LPI-ModBus module. The Converter provides a communication link between FAS and the third party system that use the modbus/RTU communication protocol. Each module supports max 6 DCS, 48 zones.
  • Page 30: Connecting Nri With Telephone Interface

    A2 connects with port A; port B2 connect with port B.  Connect the telephone interface device RJ-11 port to the PSTN switch or VoIP gateway, to enable the connection between X-618 system and telephone network interface. The device connection is shown as below:...
  • Page 32: Installation Inspection

    Inspection Inspect the following items after installing the X-618 system and before turning the system on:  Check if sufficient heat ventilation space is left above the DA appliance.