12-4. AFR rod function

<Function>
The AFR rod checks flame conditions during combustion. When the AFR rod detects unexpected flame
conditions, the computer board of the 520 models adjusts the fan motor speed to ensure that air and
fuel are always at a proper mixture ratio, minimizing emissions.
There are 3 types of FM speed adjustments, depending on the model & gas type, as shown the table
below.
<AFR normal range of values>
Type
Model
Gas type
MAX
Combustion
mode
MIN
If the detected AFR value is higher than the normal value, the FM speed is increased.
If the AFR value is lower than the normal value, the FM speed is decreased.
These values are read with the front cover close.
Measure the values after burning the water heater for ten minutes.
The AFR stage can be confirmed in "Diagnostic Mode". (Refer to p. 58.)
<The relationship between the AFR stage and the "10" and "99" error codes>
Type A Type B Type C
FM
FM
FM
+15%
+20%
+18%
+18%
+16.2%
+13.5%
0%
0%
0%
-9%
-12%
-10.8
Type A
T-H2-DV
LPG
25 to 50
3 to 10
Stage
"991" error code
16
15
"101" error code
Default condition
6
0
T-H2-DV/T-H2-OS Service Manual
Natural gas
31 to 48.5
20 to 46
2 to 10
(Condition of AFR stage)
0 to 5: Air-rich
In order to solve the "air excess"
problem, the fan motor speed is
automatically
combustion stage goes down.
6: Default
7 to 16: Gas-rich or Air shortage
In order to solve the "air deficiency"
problem, the fan motor speed is
automatically
combustion stage goes up.
15: "101" error code
16: "991" error code
65
CONFIDENTIAL
Type B
Type C
T-H2-OS
LPG
Natural gas
19 to 40
3 to 18
2 to 15
decreased
increased
and
Ver. 1.01
(Unit: μA)
and
AFR
AFR