Getting Acquainted

Congratulations upon your selection of this CASIO watch. To get the most out
of your purchase, be sure to carefully read this manual and keep it on hand
for later reference when necessary.

Applications

The built-in sensors of this watch measure altitude, barometric pressure,
temperature and underwater depth. Measured values are then shown on the
display. Such features make this watch useful when hiking, mountain
climbing, skin diving, or snorkeling, or when engaging in other such outdoor
activities.
For a watch with the elapsed time bezel
Elapsed time bezel

General Guide

• The illustration below shows which buttons you need to press to navigate
between modes.
• In any mode, press L to illuminate the display.
Countdown
Timer Mode
C
C
Alarm Mode
Hand Setting Mode
C

Timekeeping

Month – Day
Day of week
Seconds
Hour : Minutes
PM indicator
To set the digital time and date
1. In the Timekeeping Mode, hold down A until the seconds start to flash,
which indicates the setting screen.
2. Press C to move the flashing in the sequence shown below to select other
settings.
Seconds
Day
Operation Guide 2782
Rotate the elapsed time bezel to align the
mark with the minute hand.
After that, the number of minutes that elapse is
indicated by how far the minute hand has moved
from
.
C
C
This watch features separate digital and analog
timekeeping. The procedures for setting the
digital time and analog time are different.
• Whenever you need to adjust both the digital
and the analog time settings, make sure you
adjust the digital setting first.
Digital Time and Date
Use the Timekeeping Mode to set and view a
digital display of the current time and date. When
setting the digital time, you can also configure
settings for the 12/24-hour format.
Hour
Minutes
12/24-Hour
Format
Month
Year
• The measurement functions built into this watch are not intended for
taking measurements that require professional or industrial precision.
Values produced by this watch should be considered as reasonable
representations only.
• This watch is intended for use up to skin diving and snorkeling. Never
use this watch while scuba diving.
• Never operate the buttons of the watch while underwater.
• CASIO COMPUTER CO., LTD. assumes no responsibility for any loss,
or any claims by third parties that may arise through the use of this
watch.
About This Manual
(Light)
• From the Timekeeping Mode, you can press B to directly enter the
Barometer/Thermometer Mode or D to enter the Altimeter Mode. You can
also use B and D to switch between the Barometer/Thermometer Mode
and the Altimeter Mode.
Timekeeping Mode
Press C.
3. When the setting you want to change is flashing, use D and/or B to
change it as described below.
Setting
Seconds
Hour, Minutes
12/24-Hour
format
Year, Month,
Day
4. Press A to exit the setting screen.
Note
• Resetting the seconds to 00 while the current count is in the range of 30 to
59 causes the minutes to be increased by 1. In the range of 00 to 29, the
seconds are reset to 00 without changing the minutes.
• With the 12-hour format, the P (PM) indicator appears on the display for
times in the range of noon to 11:59 p.m. and no indicator appears for times
in the range of midnight to 11:59 a.m.
• With the 24-hour format, times are displayed in the range of 0:00 to 23:59,
without any indicator.
• The 12-hour/24-hour timekeeping format you select in the Timekeeping
Mode is applied in all modes.
• The year can be set in the range of 2000 to 2039. The day of the week is
calculated automatically in accordance with the date you set.
• The watch's built-in full automatic calendar automatically makes allowances
for different month lengths and leap years. Once you set the date, there
should be no reason to change it except after you have the watch's battery
replaced.
Warning!
• Button operations are indicated using the
letters shown in the illustration.
• Each section of this manual provides you with
the information you need to perform operations
in each mode. Further details and technical
information can be found in the "Reference"
section.
• Most of the display examples in this manual
show only the digital display, without the analog
hands, as shown in the lower illustration.
Press B.
Barometer/
Thermometer Mode
Press C.
Screen
Button Operations
Press D to reset the seconds to 00.
Use D (+) and B (–) to change the setting.
Use D to toggle between 12-hour (12H)
and 24-hour (24H) timekeeping.
Use D (+) and B (–) to change the setting.
Press D.
1

Advertisement

Table of Contents
loading

Summary of Contents for Casio 2782

  • Page 1: Getting Acquainted

    Getting Acquainted Warning! Congratulations upon your selection of this CASIO watch. To get the most out • The measurement functions built into this watch are not intended for of your purchase, be sure to carefully read this manual and keep it on hand taking measurements that require professional or industrial precision.
  • Page 2 Operation Guide 2782 Setting the Analog Time About Barometric and Temperature Measurements Perform the procedure below when the time indicated by the analog hands • Barometric pressure and temperature measurement operations are performed as soon as you enter the Barometer/Thermometer Mode. After does not match the time of the digital display.
  • Page 3 Operation Guide 2782 To take an altitude reading What is “a dive”? Pressing D in the Timekeeping Mode or in the A dive starts when you pass a depth of one meter (about four feet) while the watch is in the Depth Gauge Mode. The dive ends when you are on the...
  • Page 4: Countdown Timer

    Take the watch to the place auto-repeat automatically restarts the countdown from the countdown start where you purchased it or to some other CASIO retailer to have it checked. time you set. Turning off auto-repeat causes the countdown to stop and the •...
  • Page 5 Operation Guide 2782 3. Press C to move the flashing between the hour and minute settings. To use the countdown timer 4. While a setting is flashing, use D (+) and B (–) to change it. Press D while in the Countdown Timer Mode to start the countdown timer.
  • Page 6 Whenever you have a sensor malfunction, be sure to take the watch to your original dealer or nearest authorized CASIO distributor as soon as • To give temperature measurement priority, remove the watch from your possible.
  • Page 7 Operation Guide 2782 3. After waiting four or five seconds, press C to move the flashing in the • The RECOVER indicator will flash on the display if you use the light or alarms a number sequence shown below. of times during a short period. All of the...
  • Page 8 Operation Guide 2782 3. After waiting four or five seconds, C to move the flashing to the pressure sensor calibration setting. • At this time, or the barometric pressure value should be flashing on the display. • If or the pressure value does not...

Table of Contents