Specifications; Generator - Generac Power Systems 7 kW NG Repair Manual

Standby generator air-cooled product with nexus control, 7 kw ng, 8 kw lp, 9 kw ng, 10 kw lp, 13 kw ng, 14 kw lp, 15 kw ng, 15 kw lp, 16 kw ng, 17 kw lp, 18 kw ng, 20 kw lp
Hide thumbs Also See for 7 kW NG:
Table of Contents

Advertisement

Specifications

Unit
Rated Max. Continuous Power Capacity
(Watts*)
Rated Voltage
Rated Voltage at No-Load (NG)
Older controller P/N 0H6680A
Newer controller P/N 0H6680B
Rated Max. Continuous Load Current
(Amps)
240 Volts (LP/NG)
Main Line Circuit Breaker
Circuits*** 50A, 240V
40A, 240V
30A, 240V
20A, 240V
20A, 120V
15A, 120V
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement
Weight (unit only in lbs.)
Enclosure
Normal Operating Range
* Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.
Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F)
ambient temperature.
** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each circuit must not exceed the value
stated for the 240 volts.
*** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the transfer switch.
STATOR WINDING RESISTANCE VALUES / ROTOR RESISTANCE*
Power Winding: Across 11 & 22
Power Winding: Across 33 & 44
Sensing Winding: Across 11 & 44
Excitation Winding: Across 2 & 6
Rotor Resistance
* Resistance values shown are based on new windings at 20
connections included in the circuit being tested.
Page 4

GENERATOR

8 kW
10 kW
13 kW
7,000 NG
9,000 NG
13,000 NG
8,000 LP
10,000 LP
13,000 LP
33.3/29.2
41.6/37.5
54.2/54.2
35 Amp
45 Amp
55 Amp
-
-
-
1
1
1
1
-
3
3
3
5
340
387/353
Steel
Steel/Aluminum
This unit is tested in accordance to UL 2200 standards with an operating temperature of 20° F (-29° C) to 122°F. (50° C). For
areas where temperatures fall below 32° F (0° C), a cold weather kit is highly recommended. When operated above 77° F (25° C)
there may be a decrease in engine power. (Please reference the engine specifications section).
8 kW
10 kW
0.1660-
0.1895-
0.1003-
0.1930
0.2203
0.1660-
0.1895-
0.1003-
0.1930
0.2203
0.378-.4392
0.425-0.4938
0.2484-
1.0318-
1.0935-
0.876-1.017
0.1930
1.2708
6.30-7.32
6.30-7.32
7.58-8.80
°
C. Actual readings may vary based on type of meter used and any other components or
14 kW
15 kW
13,000 NG
15,000 NG
14,000 LP
15,000 LP
240
250-254
240-244
58.3/54.2
62.5/62.5
60 Amp
65 Amp
1
-
1
1
1
1
-
-
-
1
1
1
4
6
5
4
4
5
1
2
60 Hz
1
Group 26R, 12 Volts and 525 CCA Minimum
439
439
455/421
Steel
Steel
Steel/Aluminum
13 kW
14 kW
15 kW
0.1003-
0.0746-
0.1165
0.1165
0.0866
0.1003-
0.0746-
0.1166
0.1166
0.0866
0.2484-
0.197-0.229
0.2887
0.2888
0.876-1.018
0.780-0.906
7.58-8.81
8.37-9.72
16 kW
17 kW
20 kW
16,000 NG
16,000 NG
18,000 NG
16,000 LP
17,000 LP
20,000 LP
66.6/66.6
70.8/66.6
83.3/75.0
65 Amp
65 Amp
100 Amp
1
1
1
1
-
-
1
1
5
5
5
5
439
455/421
Steel
Steel/Aluminum
Aluminum
16 kW
17 kW
20 kW
0.0746-
0.0746-
0.0415-
0.0866
0.0866
0.0483
0.0746-
0.0746-
0.0415-
0.0866
0.0866
0.0483
0.197-0.229
0.197-0.229
0.137-0.1594
0.780-0.906
0.780-0.906
0.7318-
0.8504
8.37-9.72
8.37-9.72
9.54-11.10
-
-
-
-
-
-
450