  • Page 1 Telemetry Transmitter Installation Guide Models covered Tx1000 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323 842728...
  • Page 2: Transmitter Variants

    INTRODUCTION The BBV Tx1000 Series transmitters are very simple to use in multi-camera CCTV systems. They are easily installed into either a new or an existing system. Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01...
  • Page 3 AUTOPAN IRIS FOCUS IRIS FOCUS CAMERA SELECT CAMERA SELECT PATROL PRESET MONITOR PATROL PRESET MONITOR B B V B B V LENS TILT LENS TILT KEYBOARD 1 OPTIONAL 2ND KEYBOARD Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 3 of 14...
  • Page 4 LAYOUT OF THE BBV Tx1000 KEYPAD Connections Having mounted the base unit on the wall or in a rack, continue as follows: 1. Connect the keypad to 9-pin d socket marked "Keypad 1". 2. Connect a BNC cable from output M1 to the keypad, and connect the other keypad connection to Monitor 1.
  • Page 5 This key may be used by the installer to activate a panic record facility on a VCR, or to activate a video printer, etc. These contacts are low-voltage, low-current only. IMPORTANT: DO NOT CONNECT THESE CONTACTS TO MAINS POTENTIALS Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 5 of 14...
  • Page 6: Keypad Functions

    Lens Action is activated. Inching is achieved by repeated quick presses of the key. Auxiliary Function Switches There are four auxiliary function switches on the BBV Tx1000 keypad. These are Wash, Wipe, Autopan and Lights. Their functions are as follows: Wash...
  • Page 7: Iris Level Program

    Option 3. Note: There is a 15-second time-out, after reaching the correct aperture setting, in which to program the iris setting. When this time period expires, the iris reverts to its default setting. Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 7 of 14...
  • Page 8 To erase a preset, press the Program key to gain access to the menu. Select Option 4 and when the display changes to "Erase Preset", select the number of the preset to be erased. Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 8 of 14...
  • Page 9: Patrol Settings

    PATROL SETTINGS There are two patrol commands that can be started by the BBV Tx1000. They are activated by pressing the Patrol key and either Key 1 or Key 2. All other keys are ignored. Their function is to enable a string of presets to be selected in turn, switching between presets after a fixed period of time (nominally 30 seconds).
  • Page 10: Spare Outputs

    There are four spare outputs, which are momentary-action, for use as relay drivers. They are activated by pressing simultaneously the # key and one of the auxiliary keys. An on-screen display confirms which output has been activated. Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 10 of 14...
  • Page 11: Alarm Inputs

    AUTOPAN IRIS FOCUS ZOOM TIME LAPSE CAMERA SELECT PATROL PRESET MONITOR B B V LENS TILT Do NOT connect mains potentials to these contacts they are low voltage contacts only!! Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 11 of 14...
  • Page 12: Alarm Contacts

    If the local alarm feature of any receiver is used then set the alarm pre-set position to 16 from the Tx1000 menu. The standard AC Rx400P receiver can be programmed to goto pre-set position 1-15 during an alarm.
  • Page 13 MIXED COAX AND TWISTED PAIR SYSTEMS The Tx1000 series of transmitters copes automatically with a mixture of coax and twisted pair connected receivers, directing the telemetry signal to the relevant interface. The only requirement is that the installer should connect the twisted pair cable to the telemetry output corresponding to the video input.
  • Page 14: Additional Information

    After movement commands on keypad one, there is a 20-second or so lock-out period before control is given to keypad two. Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 14 of 14...