SYMPTOM
POSSIBLE CAUSE
1. continued
F. continued
2. Flow adequate
A. Shower heater is on
but water too
the 'LOW' power
cold.
setting.
B. Water flow too high.
3. Water too hot.
A. Water flow too low.
B. Sprayplate blocked
with scale and
debris.
C. Water pressure too
low.
4. Water runs from
A. Handset Blocked.
around hose.
Pressure relief
device (PRD)
has operated
due to excess
pressure build-
up.
B. Hose damaged or
kinked.
5. Temperature
A. Thermal cut-out is
varies while
operating, normally
showering,
making a 'click' as it
cycling hot/
does so.
cold.
B. Input pressure is
below the minimum
required (see 3.2).
Flow is unstable.
REMEDY
4. Release 'LOW' and 'START/STOP' buttons.
5. Press 'START/STOP', the shower will be reset to
previous settings.
A. Ensure that the shower is on 'HIGH' setting, where
applicable.
B. Reduce the flow by turning the water control knob
clockwise slowly. NOTE: If the knob is turned too far
clockwise, the safety pressure switch inside the shower
will turn off the heating elements. This is apparent
when the 'reduce temp' light starts flashing. If this
happens, turn the knob anticlockwise until the light
stops flashing.
A. Increase the flow by turning the water control knob
anticlockwise slowly.
B. Clean the handset sprayplate.
C. Switch to 'LOW' setting, if applicable.
A. Clean out the sprayplate as in 'Maintenance' Section 8.
Call a service engineer to remove the front cover and
reset the PRD by removing the bent bracket, pushing
the black outlet boss back into the heat exchanger, and
refitting a new bracket.
If the fault occurs again without the hose being
damaged or the handset blocked, contact our Service
Department.
B. Replace kinked or damaged hose and be careful not to
turn water control knob too far anticlockwise. Reset as
in 'A'.
A. Increase the flow by turning the water control knob
anticlockwise. Clean the handset and sprayplate.
B. Ensure that your stop cock and servicing valve are fully
open. If they are, ask your installer or the local water
company to check that the running pressure is above
the minimum required (see 3.2).
18
CONTENTS
Internal components .......................... p2
Wiring diagram .................................. p2
TECHNICAL SPECIFICATIONS ........ p3
IMPORTANT INFORMATION ............ p4
How an instant electric shower works p5
SITING AND PLUMBING .................. p6
Things you must do ........................... p6
Things you must not do ..................... p7
ELECTRICAL INSTALLATION ........... p8
CONNECTING TO SERVICES ......... p9
Preparation ........................................ p9
Cable entry ........................................ p9
Pipe entry ........................................ p10
Plumbing ......................................... p11
Electrics ........................................... p11
Fitting the front cover ....................... p12
Commissioning ................................ p12
User Protect System ........................ p13
Inspect Handset light ....................... p13
Setting the Descale Time ................. p13
Setting Descale Timer to zero .......... p14
GUARANTEE & SERVICE POLICY p14
ENVIRONMENTAL INFORMATION p14
USER INFORMATION ..................... p14
Maintenance .................................... p16
Inspection ........................................ p16
FAULT FINDING ..................... p17 - p19
Address and phone numbers ........... p20
Approved Spares Stockists .............. p20

1 TECHNICAL SPECIFICATIONS

1.1 CONNECTIONS
Inlet connection -15mm ext. diameter
spigot for
compression fitting.
Water entry point - Top,bottom, rear and
right hand side.
Cable entry point - Top, bottom and rear
1.2 ELECTRICAL
Nominal Power Rating
P
o
w
e
r r
t a
n i
g
P
o
w
e
M
o
d
l e
@
2
4
0
V
@
9
5
0
2
1
6
4
1
8
5 .
k
W
3 (
5
) A
7
8 .
k
W
9
5
0
2
1
5
4
8
9
8 .
k
W
4 (
1
) A
9
0 .
k
W
9
5
0
2
1
5
4
9
1
0
8 .
k
W
4 (
5
) A
9
9 .
k
W
1.3 MATERIALS
Backplate, cover
and control knob - ABS
Elements
- Copper sheathed rod
type
1.4 DIMENSIONS
Height - 297mm
Width - 186mm
Depth - 86mm
1.5 STANDARDS AND APPROVALS
Complies with the requirements of
EN 60335-2-35.