005639
When the tool is not to be used for an extended period of
time, lubricate the tool using pneumatic tool oil and store
the tool in a safe place. Avoid exposure to direct sunlight
and/or humid or hot environment.
005640
005641
Maintenance of compressor, air set and air
hose
1
004317
1. Drain cock
8
1
004318
After operation, always drain the compressor tank and
the air filter. If moisture is allowed to enter the tool, It may
result in poor performance and possible tool failure.
Check regularly to see if there is sufficient pneumatic oil
in the oiler of the air set. Failure to maintain sufficient
lubrication will cause O-rings to wear quickly.
004319
Keep the air hose away from heat (over 60°C, over
140°F), away from chemicals (thinner, strong acids or
alkalis). Also, route the hose away from obstacles which
it may become dangerously caught on during operation.
Hoses must also be directed away from sharp edges and
areas which may lead to damage or abrasion to the hose.
Thinner
004320
To maintain product SAFETY and RELIABILITY, repairs,
any other maintenance or adjustment should be
performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
1. Air filter
1. Oiler
2. Pneumatic oil