Filter Board Replacement (Three Cook Zone Module) - Electrolux E36IC75FSS Service Manual

Icon designer series 36” induction drop-in cooktop
Hide thumbs Also See for E36IC75FSS:
Table of Contents

Advertisement

COMPONENT ACCESS AND SERVICE PROCEDURES
Filter Board Replacement (Two Cook Zone Module)
Lift the right side of the fi lter board high enough to
clear the cooling fan and pull in the direction shown
to release the opposite side from the housing (Fig
27).
To install the replacement fi lter board perform the
previous steps in reverse order.
Fig. 27

Filter Board Replacement (Three Cook Zone Module)

To remove and replace the fi lter board in the three
cook zones module it is necessary to disconnect
X12
the power cable wires and copper jumpers at the
terminal block on the underside of the board. Be-
gin by disconnecting all cables and wires from the
board.
Remember to use the special cable removal tool
to unplug the ribbon connector at terminal X12 and
X13. (Fig 27A)
X13
Fig. 27A
Tilt the housing up from the front. The power supply
wires and jumpers can be accessed from the
underside. (Fig 27B)
Fig. 27B
Page 27

Hide quick links:

Advertisement

Table of Contents
loading