Wiring Connection

Wiring Connection
WARNING : Loose wiring may cause the terminal to overheat or result
in unit malfunction.
A fire hazzard may also exist.
Therefore, be sure all wiring is tightly connected.
Terminals on the outdoor unit
1(L1)
2(L2)
Power Input
RECOMMENDATION: The power cord connected to the outdoor unit should be
comply with the following specifications: ETL recognized and CSA certified.
The power connecting cable connected to the indoor
and outdoor unit should be comply with the
following specifications: ETL recognized and CSA
certified.
RECOMMENDATION: When using the separate wires as the power cord, please
secure the separate wires into the control box panel using tie wraps to hold all
wires together in place.
16 Air Conditioner
1(L1) 2(L2) 3
AWG12
Line voltage
(208/230V)
Terminal Block Indoor
1(L1) 2(L2)
3
4
5
TO AIR
Connected to outdoor unit
FRESH
KIT
OPTION
AWG18