Securing Stove Pipe/Liner To Flue Collar; Optional Offset Adapter Installation - Quadra-Fire 31-I ACC Installation Manual

3100-i acc wood insert automatic combustion control (acc)
Hide thumbs Also See for 31-I ACC:
Table of Contents

Advertisement

C. Securing Stove Pipe/Liner to Flue Collar
1. There are 4 pre-drilled holes in the flue collar 90 degrees
apart. Attach the flue collar to the stove pipe/liner. If the
seal is questionable use high temperature sealant such
as stove mastic Figure 19.1.
2. Attach gasket to bottom side of flue collar with a thin coat
of silicone.
Flue Collar
Figure 19.1
D. Optional Offset Adapter Installation
In some installations the flue collar and stove pipe/liner do
not always align properly. This situation may be remedied
by using the optional offset adapter. See Appliance Dimen-
sions page for the amount of distance this accessory can
telescope between the flue collar and stove pipe/liner.
1. Remove the cast iron flue collar from the appliance and
flip it upside down. Using the larger #7 drill bit supplied,
drill through all 8 countersunk locations. Figure 19.2.
2. Slide the gasket over the flue collar and attach it to the
offset adapter using the 8-32 flathead screws provided.
Figure 19.3.
3. Adjust the offset adapter to desired distance. Drill holes
through the lower chamber as shown in Figure 19.4
using the small drill bit #26 provided.
4. Cut the gasket to the proper length and slide in between
the upper and lower chambers centered on the screw
holes. Attach the upper and lower chambers with screws
provided. Figure 19.5.
5. Repeat the process on the bottom side.
April 9, 2014
Gasket
Stove Pipe/Liner
Cast Iron Flue Located on Appliance
Figure 19.2
Figure 19.3
Once distance is established, drill holes
and secure both chambers together.
Figure 19.4
7044-225B
Drill through all 8 countersunk
locations
Figure 19.5
31-I ACC
19

Advertisement

Table of Contents
loading

Table of Contents