System power requirements

There is one power connection on the BDU. This must be connected to a 12 or 24Vdc
supply. Power requirements and consumption are as follows:
Voltage Input Minimum
Voltage Input Maximum
Total Current for ADU and BDU
(Max. @12V)
Required Fuse

Fuse

The fuse is a 15 Amp, fast blow, ATO blade fuse. The installed part is from Littelfuse,
part number 0287015. To replace the fuse, pull fuse out of fuse holder (pliers may be
needed to grip fuse) and press new fuse into fuse holder. Spare fuses are provided
with your Thuraya IP Voyager terminal.
Power Cable
The Power cable uses a Phoenix contact #1718384 PC5/3 STCL-7, 62 connector and the
pinout is shown in the Table below.
Color
Red
White
Black
The optional accessory car adapter power cable, Hughes' part number 3500472-0002,
includes a car adapter plug with a 20 Amp, 250 V fuse, and the ignition sense wire is
connected to the positive power wire in the plug.

Figure 1-3. Fitting the SIM card Cover

Table 4. System power requirements

10V
32V
12A
15A
Function
DC +
Ignition Sense +
DC -