Combustion Chamber; Baffle Plate, Thermocontrol Sensor - Baxi Bioflo User Operating Instructions Manual

Pellet central heating system boiler
Table of Contents

Advertisement

Care, cleaning and maintenance
3.6

Combustion chamber

The BAXI Bioflo is equipped with a cleaning interval display. The cleaning request for the combustion chamber
and burner pot is displayed on the info panel after 500 operating hours, and must be reset after cleaning has
finished – see section 2.8.1.6. „Boiler cleaning – Resetting the cleaning request" .
Do not open the combustion chamber door during operation. Always switch the boiler off first with the
ON/OFF button (Fig. 81) and wait until burnout mode has finished. It is essential to let the boiler cool
down before cleaning.

3.6.1 Baffle plate, thermocontrol sensor

– Open the combustion chamber door, lift the baffle plate at the right and guide it out at an angle, sloping
down to the left – Fig. 82, Removing the baffle plate and fly ash.
– If necessary, remove fly ash from the thermocontrol sensor with a cleaning brush. The thermocontrol sen-
sor is located at the top left of the combustion chamber behind the baffle plate – Fig. 83.
Assembly:
By working through these steps in reverse order.
Fig. 81
Fig. 83
Switching off BAXI Bioflo
Cleaning the thermocontrol sensor
(with cleaning brush)
Fig. 82
Removing and cleaning the baffle plate
Thermocontrol sensor
34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bioflo 12 kw pear

Table of Contents