Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse type:
Main—F1-30 amp, blade-type
Charge Circuit—F2-25 amp, blade-type
1. Remove the screws securing the control panel to the
machine.
Note: Retain all fasteners.
2. Lift the control pane up to access the main wiring
harness and fuse block (Figure 37).
3. To replace a fuse, pull out on the fuse to remove it
(Figure 37).
2
Figure 37
1. Main—30 amp
4. Return the control panel to its original position.
Note: Use the screws removed previously to secure
the panel to the machine.
1
G014921
2. Charge circuit—25 amp
Drive System
Maintenance

Checking the Tire Pressure

Service Interval: Every 25 hours—Check tire pressure.
Maintain the air pressure in the front and rear tires as
specified. Uneven tire pressure can cause uneven cut. Check
the pressure at the valve stem (Figure 38). Check the tires
when they are cold to get the most accurate pressure reading.
Refer to the maximum pressure suggested by the tire
manufacturer on the sidewall of the caster wheel tires.
Inflate the rear drive-wheel tires to 82 kPa (12 psi).
1. Valve stem
30
Figure 38