System Operation; Maintenance - Lennox Elite XC13 Installation Instructions Manual

Elite series
Table of Contents

Advertisement

Table 4. Normal Operating Pressures (Liquid +10 and Suction +5 psig)
IMPORTANT
XC13
5F (5C) *
Expansion Valve
65 (18)
70 (21)
75 (24)
80 (26)
85 (29)
90 (32)
95 (35)
100 (38)
105 (41)
110 (43)
115 (46)
Fixed Orifice
65 (18)
70 (21)
75 (24)
80 (26)
85 (29)
90 (32)
95 (35)
100 (38)
105 (41)
110 (43)
115 (46)
*Temperature of the air entering the outside coil.
**Typical pressures; indoor unit match up, indoor air quality equipment, and indoor load causes pressure variance

System Operation

The outdoor unit and indoor blower cycle on demand from
the room thermostat. When the thermostat blower switch
is in the ON position, the indoor blower operates
continuously.
HIGH PRESSURE SWITCH
XC13 units are equipped with a high-pressure switch that
is located in the liquid line of the compressor as illustrated
in Unit Dimensions on page 2. The switch is a Single Pole,
Single Throw (SPST), manual−reset switch with red cap
that is normally closed and removes power from the
compressor when discharge pressure rises above factory
setting at 590 + 10 psi.
DISCHARGE THERMOSTAT
Each XC13 unit is equipped with a discharge thermostat
located in the discharge line of the compressor. The switch
(SPST, auto−reset, normally closed) and removes power
from the compressor when discharge temperature
exceeds the factory setting of 220
506120−01 03/10
Use this table to perform maintenance checks; it is not a procedure for
charging the system. Minor variations in these pressures may be due to
differences in installations. Significant deviations could mean that the system
is not properly charged or that a problem exists with some component in the
system.
−018
−024
233 / 132
244 / 137
251 / 133
263 / 138
265 / 133
285 / 139
292 / 135
307 / 140
314 / 136
329 / 141
338 / 137
354 / 142
362 / 138
379 / 143
388 / 140
404 / 144
415 / 141
438 / 145
444 / 142
464 / 147
475 / 143
495 / 148
233 / 121
246 / 126
250 / 124
265 / 129
270 / 128
286 / 132
291 / 131
307 / 135
313 / 134
330 / 137
335 / 136
353 / 140
359 / 138
378 / 142
383 / 140
402 / 143
409 / 142
428 / 145
436 / 145
456 / 147
464 / 147
486 / 149
º
º
F +5
F.
−030
−036
Liquid Line Pressure / Vapor Line Pressure **
248 / 127
263 / 135
263 / 131
281 / 138
284 / 132
302 / 140
307 / 134
325 / 142
330 / 135
349 / 142
355 / 136
375 / 143
380 / 137
404 / 144
407 / 138
433 / 145
434 / 139
462 / 147
465 / 141
494 / 149
497 / 142
527 / 150
245 / 123
261 / 134
265 / 126
281 / 136
286 / 129
301 / 138
308 / 132
324 / 140
331 / 135
346 / 142
355 / 138
371 / 144
380 / 140
396 / 146
405 / 142
422 / 148
431 / 144
448 / 150
458 / 146
477 / 151
487 / 148
506 / 153
FILTER DRIER
A filter drier is factory-installed as illustrated in Unit
Dimensions on page 2, with each XC13 unit to ensure a
clean, moisture−free system. A replacement filter drier is
available from Lennox. Refer to Lennox Repair Part
Program.

Maintenance

Improper
service or maintenance can cause personal injury,
loss of life, or damage to property.
Installation and service must be performed by a
licensed professional installer (or equivalent) or a
service agency.
At the beginning of each cooling season, the system
should be checked as follows:
1. Clean and inspect the outdoor coil. The coil may be
flushed with a water hose. Ensure the power is turned
off before you clean the coil.
Page 26
−042
−048
235 / 128
235 / 132
249 / 129
254 / 132
268 / 130
276 / 134
290 / 132
298 / 134
313 / 133
323 / 135
337 / 134
350 / 137
364 / 134
377 / 138
389 / 135
406 / 140
416 / 136
430 / 141
445 / 137
464 / 142
473 / 139
495 / 143
236 / 119
247 / 125
250 / 121
266 / 128
269 / 124
286 / 131
290 / 127
307 / 133
312 / 130
329 / 135
334 / 133
353 / 138
360 / 136
377 / 140
385 / 139
403 / 142
413 / 141
428 / 144
438 / 143
455 / 146
466 / 145
483 / 147
WARNING
installation,
adjustment,
−060
241 / 130
260 / 130
280 / 132
299 / 134
321 / 135
344 / 134
371 / 135
400 / 137
428 / 139
458 / 141
484 / 142
248 / 124
266 / 126
288 / 130
309 / 133
330 / 135
354 / 138
377 / 140
406 / 142
431 / 144
457 / 146
484 / 148
alteration,