deration - At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either using gas that has been derated by
the gas company or by changing the burner
orifice to a smaller size as regulated by the local
authorities having jurisdiction and by the (USA)
National Fuel Gas Code NFPA 54/ANSI Z223.1
- latest edition or, in Canada, the CAN/CSA-
B149.1 - latest edition.
Burn-in period
During the first few fires of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process.
Depending on your use, the burn-in period may
take a few hours or a few days.
Keep Your House WeLL VentiLated
durinG tHe curinG process. tHe odor
and HaZe eMitted durinG tHe curinG
process can Be Quite noticeaBLe and
MaY set oFF a sMoKe detector.
If an optional blower is installed, Do Not turn
it on during the Burn-In period.
A white film may develop on the glass front
during the first few fires as part of the curing
process. The glass should be kept clean during
the first two weeks of use to prevent the film from
baking on (making it very difficult to remove).
See Cleaning Glass on page 6.
Gas controls/control compartment
access
The gas controls can be found behind the control
compartment access door.
removing control compartment door:
Open the panel by gently lifting it upward and
forwards. Slide the door, first to one side and
then the other, so the tabs clear both of the
locating holes.
On millivolt systems, the piezo igniter, HI/LO
flame adjustment knob, and pilot and main
gas OFF/ON control knob are located below
the glass panel enclosure. The gas valve for
electronic systems is also located below the
glass enclosure panel. See Figure 2.
reinstalling control compartment door:
To reinstall, insert the tabs on each side of the
door into the corresponding holes in the control
compartment opening, one side first then the
other. To close, pull the door gently up and
close by pushing forward and pushing the top
edge down into the groves at the brackets until
it locks in place.
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
control compartment door tab
Figure 1
operation and care oF Your
appLiance
caution: tHe Vent terMination is Hot
WHiLe in operation and For a period
oF tiMe FoLLoWinG tHe use oF tHe Fire-
pLace. to preVent contact WitH Hot
surFaces, We recoMMend tHe use oF
a terMination Guard. see paGe 17 For
orderinG inForMation.
The standard controls for appliance operation
are located behind the panel below the appli-
ance front glass enclosure panel (Figure 2 ).
Optional control switches are also available
(see pages 15 and 17 - Remote Wall Switch,
Remote Control or Wall Thermostat).
WarninG: YounG cHiLdren sHouLd Be careFuLLY superVised WHen tHeY
are in tHe saMe rooM as tHe appLiance. toddLers, YounG cHiLdren and
otHers MaY Be susceptiBLe to accidentaL contact Burns. a pHYsicaL
Barrier is recoMMended iF tHere are at risK indiViduaLs in tHe House.
to restrict access to a FirepLace or stoVe, instaLL an adJustaBLe saFetY
Gate to Keep toddLers, YounG cHiLdren and otHer at risK indiViduaLs out
oF tHe rooM and aWaY FroM Hot surFaces.
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance. Familiarize
yourself with the gas control valve that your
appliance uses. Refer to Figure 1 for access
to the gas control valve.
Millivolt appliances - Appliances with
Millivolt systems will be fitted with the gas
control valve shown in Figure 3.
electronic appliances - Appliances with
electronic systems will be fitted with the
electronic valve shown in Figure 4.
Millivolt appliances - To light millivolt appli-
ances refer to Figure 2. Detailed lighting instruc-
tions are found on pages 18 and 19 . Millivolt
appliance lighting instructions may also be
found on the pull out lighting instruction labels
attached to the gas control valve.
Once the pilot is lit, the main burner may be
turned ON and OFF using wall switch, remote
control, optional on unit rocker switch (FRS),
or wall thermostat. To operate: Toggle the
switch between its ON and OFF positions.
If your millivolt appliance is equipped with an
optional remote switch kit (wall switch, remote
control, rocker switch, or wall thermostat) and
the pilot is lit, the appliance main burner may be
turned on and off using the optional switch.