122
7-4. BIAS SETTING ADJUSTMENT
Before adjusting the bias setting
:
a. Connect the measuring instruments as shown
in Fig. 7-3.
b. Load a blank tape and put the deck in the
record/pause mode.
c. Apply a -14 dBV/400 Hz signal to the LINE
1 or 2 terminal.
d. Adjust the INPUT (LEFT/RIGHT) level con
trol until the VU meter reads 0 VU.
e. Adjust the OUTPUT level control so that the
OUTPUT terminal level is -10 dBV.
OSCILLOSCOPE
OSCILLATOR
'0
O
~
AMP
SPKR
'i''i'
0
~':::=,*-_~
/Ie VOLTMETER
UNIT
"'P\J!!!.j'
under TEST
OJ"""
o
0
Fig. 7-3
Bias setting at position METAL
1) Set the EO and B I AS switches to META
L.
2) Al,ternately record -44 dBV signals at 400 Hz
then 10 kHz on blank tape (MTT-5072) and
reproduce them.
NOTE: The level -44 dBV is 30 dB lower than
the standard level.
3) Note readings of the OUTPUT lev'el at the
OUTPUT terminal and
che~k
that the output
levels are identical for both frequencies.
4) If the resul,t is unsatisfactory, adjust semi
fixed resistors R 15/R25.
NOTE: Turning the semi-fixed resistors clock
wise increases bias current and decreases
high frequency response; turning them
counterclockwise
increases
high
fre
quency response.
Bias settings at NORMAL and Co (Cr02)
positions
This is done in the same way as for the metal
bias setting. Refer to the following table
:
Blank tape Adjusting points
Positions
EO/BIAS switches
L
R15/R25
METAL
MTT·5072
ilBIAS METAL
R l4/R24
MIT·5061
Co(CrOz)
I
~IAS
Co(CrOz)
NORMAL
MIT·501
R13/R23
BIAS N 'ORMAL
48
7-5. RECORD LEVEL
Adjust this after the setting of the reproduce
and
b
ias levels (7-1 and 7-4) and VU meter (7-2)
is complete.
The following
items
1)
-
5) indicate the
standards levels and setting orders of each
control.
METAL
1) Connect the measuring instruments as shown
in Fig. 7-3.
2) Set the BIAS and EO switches to METAL and
the MONITOR switch to SOURCE.
3) Load blank tape (MTI-5072) and set the deck
in the record/pause mode.
4) Apply -14 dBV/400 Hz signals to LINE 1 or
2 .
5) Adjust the INPUT (LEFT/RIGHT) level con
trol until the VU meter reads 0 VU
.
Adjust
the OUTPUT level control so that the OUT
PUT terminal level is set to -10 dBV.
6) Set the MONITOR switch to TAPE. Record
and play the blank tape to check that the
OUTPUT level is -10 dBV
±
1 dB.
7) If satisfactory values are not obtained, adjust
semi-fixed resistors R 16/R26.
Co(Cr02) and NORMAL
This is done in the same way for metal tape.
Perform adjustment referring to the following
table.
Positions
EO/BIAS switches Blank tapes Adjusting po ints
METAL
METAL
MTT·5072
R16/R26
Co(CrO z)
Co(CrOz)
MIT·5061
R17/R27
NORMAL
NORMAL
MTT-50l
R18/R28
7-6. OVERALL FREQUENCY RESPONSE
METAL
Obtain the standard setting according to proce
dures 1) -
6) of 7-5. and
ch
eck the record/
reproduce sigr.als.
1) Obtain -44 dBV by decreasing the input
signal level by 30 dB and record and play it
on blank tape (MTT-5072).
Change the input signal level and confirm that
the level at 12 kHz is within ±2 dB of the level
at 400 Hz. Also confirm at high tape speed.
I f
the
response
is
unsatisfactory,
check
whether the record/reproduce head is
-
d irty or
set correctly. It is also necessary to check the
bias level setting.
NOTE: Perform this adjustment with the N R
SYSTEM switch set
OUT.