9.
At this time, make sure all gas, exhaust and electrical connections are complete. Plug dryer in, and
check operation by using the check list below.
10.
(GAS MODELS ONLY)
The burner may not ignite initially due to air in the gas line. Allowing the dryer to operate on a heat
setting will purge the line. If the gas does not ignite within five minutes, turn the dryer off and wait
5 minutes. Be sure the gas supply to the dryer has been turned on. In order to confirm gas ignition,
check the exhaust for heat.
FINAL INSTALLATION CHECK LIST
n
Dryer is plugged into electrical outlet and is properly grounded.
n
Exhaust duct work is hooked up and joints taped.
n
Plastic flexible duct is NOT used.
n
Use rigid or stiff walled flexible metal vent material.
n
Dryer is level with all legs firmly on the floor, with the lock nuts tightened.
n
Vinyl feet have been installed.
n
Gas Models – gas is turned on, there are no gas leaks.
n
Dryer runs, heats, shuts off.
n
Demonstrate use to consumer.
HOUSEHOLD INSTALLATION ACCESSORIES
• Vent hood – 4" (10.16 cm) opening – 059129
• Aluminum pipe – 4" x 24" (10.16 cm x 60.96 cm) – 059130
• Aluminum elbow – 4" (10.16 cm) – 059131
• Aluminum window plate – 15" x 20" (38.10 cm x 50.80 cm) – 4" (10.16 cm) hole – 059134
• Flexible aluminum vent duct – 4" (10.16 cm) diameter – 38" (81.28 cm) length stretches to 8' (2.44 cm) –
304353
• Clamp for flexible aluminum duct – 304630
• Exhaust duct kit for base or left side ex h a u s t i n g – 12001453
• Rectangular vent kit – 059144
• Dacron lint bag – 311353
• NATURAL to LP conversion kit – 306195
• LP to NATURAL conversion kit – 306204
• Anchor bracket kit – 303740
• Heating element conversion kit, 208V., not for Canada– 308590
• Grounding wire – 311155
• Grounding clamp – 301548
• Power cords – 240 v, 30 A
4' (121.9 cm) – 3-wire – 33001780
5' (152.4 cm) – 3-wire – 33001822
6' (182.9 cm) – 3-wire – 33001823
10' (304.8 cm) – 3-wire – 33001838
4' (121.9 cm) – 4-wire – 33001781
5' (152.4 cm) – 4-wire – 33001824
6' (182.9 cm) – 4-wire – 33001825
10' (304.8 cm) – 4-wire – 33001838
For the visually impaired, Braille labels can be placed on the control panel of the appliance. Check with your
local Association for the Blind for information on Braille label makers.