Installation; Connecting The Piping - LG MFL39817319 Installation Manual

Air conditioner multi type
Table of Contents

Advertisement

Installation

[Standard / Standard Libero / Artcool Mirror Type]

Connecting the piping

# Standard / Artcool Mirror Type
1. Prepare the indoor unit's piping and drain
hose for installation through the wall.
2. Remove the plastic tubing retainer(see the
illustration on the right) and pull the tubing
and drain hose away from chassis.
3. Route the indoor tubing and the drain hose to
the required piping hole position.
4. Insert the piping, drain hose, and the
connecting cable into the piping hole.
5. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
6. Tape the tubing and drain hose.
For right rear piping
7. Indoor unit installation
• Hang the indoor unit from the hooks at the
top of the installation plate.
• Insert the spacer etc. between the indoor
unit and the installation plate and separate
the bottom of the indoor unit from the wall.
Tape
Connecting
pipe
Drain hose
For left rear piping
Indoor unit
Installation plate
80(3 5/32)
Installation Manual 13
Installation
Drain pipe
Spacer