Payne PA3Z Installation Instructions Manual page 22

13 seer single-packaged air conditioner system with r-22 refrigerant single and three phase 2 to 5 nominal tons (sizes 024 -060)
Hide thumbs Also See for PA3Z:
Table of Contents

Advertisement

I. PRELIMINARY INFORMATION
Model No ............................................................................................................................................................
Serial No .............................................................................................................................................................
Date .....................................................................................................................................................................
Technician ..........................................................................................................................................................
Customer Information(Name/Address) .....................................................................................................................
II. PRE- -START- -UP
____ Verify that all packing materials have been removed from unit.
____ Verify that condensate connection is installed per installation instructions.
____ Check all electrical connections and terminals for tightness.
____ Check wire proximity to refrigerant tubes and sheet metal edges.
____ Check that indoor (indoor) air filter is clean and in place.
____ Verify that unit installation is level.
____ Check fan wheel propeller for location in housing and setscrew tightness.
III. START- -UP
Supply Voltage: L1- -L2 __________ L2- -L3 __________ L3- -L1 __________
Compressor Amps: L1(C) __________ L2(S) __________ L3(R) __________
Indoor Fan Amps: __________ Outdoor Fan Amps: __________
TEMPERATURE- -Cooling Mode
Outdoor Air Temperature: __________ DB ____________WB
Return- -Air Temperature: __________ DB __________ WB
Cooling Supply Air: __________DB___________WB
PRESSURES- -Cooling Mode
Refrigerant Suction __________ psig ___________kPa
Suction Line Temp* ___________
Refrigerant Discharge __________ psig ___________kPa
Discharge Temp{__________
TEMPERATURE- -Heating Mode
Outdoor Air Temperature: __________ DB ____________WB
Return- -Air Temperature: __________ DB __________ WB
Cooling Supply Air: __________DB___________WB
PRESSURES- -Heating Mode
Refrigerant Suction __________ psig ___________kPa
Suction Line Temp* ___________
Refrigerant Discharge __________ psig ___________kPa
Discharge Temp{__________
____ Verify Refrigerant charge using charging tables
*Measured at suction inlet to compressor
{Measured at liquid line leaving outdoor coil
E2008 Payne Heating & Cooling Systems D
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
START- -UP CHECKLIST
(REMOVE AND STORE IN JOB FILE)
7310 W. Morris St. D Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 04/08
22
Catalog No: IM---PA3Z---04
Replaces: IM--- PA3Z--- 03