Displays

Display
Temperature in storage tank ≥ 80 °C
E04
E12
Abnormal frost formation due to partial evaporator
blockage, moderate wind on the air outlet while running in
silent mode or strong wind on the air outlet while running in
LEG
Thermal disinfection process running
Temperature of inlet air ≥ 40 °C
HOT
Temperature of the inlet air ≤ 3 °C
COLD
Table 7
Display indications
Compress 3000 DW FO
Description
normal mode
Isolate electrical connection.
Notify authorised contractor.
Reset the system.
Do not use the silent mode in case of high possibility to
have the air outlet exposed to the wind direction.
Notify authorised contractor if the warming persists.
When temperature reaches and holds 60 °C for 35 mins,
the appliance goes back to the mode previously selected.
Occurs when air inlet is higher than 40 °C or lower than
3 °C, respectively.
The appliance will automatically shut off if "heat pump"
mode is selected. If Combi is selected the appliance will
use the electric element to heat up the water.