30 | Operation Instructions
After programming the display shows SIL with the time
bars indicating the periods the silent mode will be
activated.
Select only one day period
▶ Select the first period according to the previously
mentioned.
▶ Press "ok" for more than 3s until "Prog" and "sun symbol"
goes off.
The bar of the selected period blinks.
▶ Pres "menu" to go out of the SIL mode submenu (no
blinking).
Switching off the silent mode period
▶ Access the „Sil" function.
▶ Press „ok".
Display shows the start schedule of the 1st silent mode
period in blink mode.
▶ Use the „+" and „-" keys to set the silent mode start and
finish time to the same period.
When selecting end period of the second day period
display shows
"----".
▶ Press „ok" to confirm.
▶ Press „ok" again and hold it for more than 3s until "Prog"
and "sun symbol" goes off.
The period bar blinks.
▶ Press "menu" to go out of the SIL mode submenu (no
blinking).
The SIL menu will show no time bars.
5.6.4 „Leg" function - automatic thermal disinfection
The „Leg" function allows for the thermal disinfection process.
This bacteria elimination process will be performed
automatically once a week.
Fig. 33
„Leg" function
6 720 801 244 (2013/08)
Weekday programming of the "Leg" function
▶ Access the Leg function and press „ok".
Display with blinking indication „
▶ Press „+".
Display with blinking indication „
▶ Press „ok".
„Leg" function activated and blinking 1
Define the day of the week for disinfection.
▶ Select the day, using the „+" and „-" keys.
▶ Press „ok".
Define the time to start disinfection
▶ Select the time, using the „+" and „-" keys.
▶ Press „ok".
Upon reaching a temperature of 60 °C for more than 35
minutes, the device returns to the previously selected mode.
6720646160-17.1V
Activation of the disinfection mode
temporarily replaces any defined
programming.
DANGER: Beware of burns!
Hot water can cause serious burns.
▶ During thermal disinfection the
temperature may rise up to 66 °C at the
top of the tank.
▶ Warn all users of the danger of burns and
the need to perform thermal
disinfection.
The disinfection process will run until stored
water tank temperature reaches more than
60 °C for at least 35 minutes.
In case a programed period (P1, P2 or P3) is
selected, the auto-activation of the LEG
mode will be postponed to the next
activation of the selected programed period.
The finalization of the thermal disinfection
will have priority over the end of the
programed period,i.e., in case the
programed period is to short to allow the
conclusion of the LEG mode, the appliance
will be forced to operate until the thermal
disinfection is concluded.
" active.
" active.
st
day of the week.
Compress 3000 DW FO