Craftsman 919.165520 Owner's Manual

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.165520:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual
Permanently Lubricated
Single Stage
Portable

AIR COMPRESSOR

Model No.
919.165520
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D27221 Rev. 1 9/23/02

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.165520

  • Page 1: Air Compressor

    • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D27221 Rev. 1 9/23/02...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ..........2 SPECIFICATION CHART .
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. 919-165520 Max. Developed HP Bore 2.375" Stroke 1.35" Voltage-Single Phase 120V/60Hz Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
  • Page 6 HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors when it is raining or in wet conditions. electricity. Like any other electrically powered device, If it is not used properly Never operate compressor with it may cause electric shock.
  • Page 7 HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 HAZARD RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    ASSEMBLY Contents of Carton Screws (short) 1 - Air Compressor 1 - Handle Hose 1 - Grip Handle Wrap 1 - Hose Wrap Handle Handle Grip Screws 2 - Self Tapping Screw 1/4-20 x 1.25 (long) 2 - Wheels 2 - Shoulder Bolts, 3/8-16 2 - Hex Nuts, 3/8-16 Shoulder Wheel...
  • Page 11: Installation

    INSTALLATION IMPORTANT: The outlet being used HOW TO SET UP YOUR UNIT must be installed and grounded in accordance with all local codes and Location of the Air Compressor ordinances. Locate the air compressor in a clean, Make sure the outlet being used dry and well ventilated area.
  • Page 12 Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the specification chart for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
  • Page 13: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Gauge: The outlet Description of Operation pressure gauge indicates the air Become familiar with these controls...
  • Page 14: How To Use Your Unit

    Air Compressor Pump (not Motor Overload Protector: The shown): Compresses air into the motor has an automatic reset thermal air tank. Working air is not available overload protector. If the motor until the compressor has raised the overheats for any reason, the air tank pressure above that overload protector will shut off the required at the air outlet.
  • Page 15: How To Start

    Open the drain valve fully How to Start: (counter-clockwise) to permit air Turn the On/Auto/Off lever to to escape and prevent air "AUTO" and allow tank pressure pressure build up in the air tank during the break-in period. to build. Motor will stop when tank pressure reaches "cut-out"...
  • Page 16: Maintenance

    MAINTENANCE Customer Responsibilities Daily or Before Every Every after each Yearly each hours hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles To Check Safety Valve automatically when If the safety valve power is on.
  • Page 17 If dirty, rinse air filter with warm water and squeeze dry. Water will condense in the air Replace air filter. tank. If not drained, water will Replace filter cover. corrode and weaken the air tank NOTE: If the air filter is extremely causing a risk of air tank rupture.
  • Page 18: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles automatically when Outlet Tube power is on. When doing Pressure Maintenance, you may be exposed Relief Check to voltage sources, compressed air Tube Valve or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
  • Page 19 12. Replace the outlet tube and Remove the outlet pressure tighten nuts. gauge, tank pressure gauge, and quick connect (if equipped) from 13. Replace shrouds and console. the regulator. 14. Perform the Break-in Procedure. See "Break-in Procedure" in the Remove the regulator. Operation section.
  • Page 20: Storage

    STORAGE Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled After the water has been drained, maintenance as necessary.
  • Page 21: Troubleshooting Guide

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Replace. Damaged regulator. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 24: Repair Parts

    AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919.165520 Torque 15 -25 In-Lbs Torque 100-120 In-Lbs Torque 9-12 Ft-Lbs Torque 5-7 Ft-Lbs 24- ENG D27221...
  • Page 25: Parts List

    PARTS LIST Air Compressor Model Number 919.165520 PART NO. DESCRIPTION D23362 Front Shroud D24233 Foam Filter Pump Assembly SSG-3105 O-Ring SSP-7821-1 Nut Tubing 3/8" OD AC-0097 Outlet Tube AC-0028 Pressure Relief Tube D21927 Safety Valve AC-0558 Grip D20155 Ring SUDL-413-2...
  • Page 26 PUMP DIAGRAM Air Compressor Model Number 919.165520 Torque 7-10 Ft-Lbs 79-4 79-3 79-2 Torque 42-48 In-Lbs Torque 100-120 In-Lbs Torque 100-120 In-Lbs 26- ENG D27221...
  • Page 27 PARTS LIST Air Compressor Model Number 919.165520 PART NUMBER DESCRIPTION SSF-586 Screw 1/4-20 UNC x .75 AC-0108 SSF-615 Screw 1/4-20 UNC Z-AC-0140 Eccentric Bearing Z-D23360 Motor >x 78 --------- Cylinder Sleeve > 79 --------- Connecting Rod Assembly >x 79-2 --------- Compression Ring >x 79-3 ACG-29...
  • Page 28: Español

    CONTENIDO GARANTÍA ............28 CUADRO DE ESPECIFICACIONES .
  • Page 29: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-165520 Máx. HP desarrollado Diámetro interior 2,375 po (60,4 mm) Carrera 1,35 po (34,3 mm) Tensión monofásica 120V/60Hz Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 33 Galones (124,9 litros) Presión de corte de entrada Presión de corte de salida SCFM a 40 psig...
  • Page 30 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
  • Page 31 PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido cada uso.
  • Page 32 PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.
  • Page 33 PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación.
  • Page 34 PELIGRO ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones y podría ocasionarle serias lesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiarícese con los métodos de operación y control del compresor de aire.
  • Page 35: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 36: Ensamblado

    ENSAMBLADO Contenido de la caja Tornillo 1- Compresor de aire Carrete 1- Manija para Manguera 1- Agarradera de manija 1- Carrete para Manguera Tornillo Agarradera Mango de manija 2- Tornillo Autorroscante 1-20 x 1.25 2- Ruedas Arandela 2- Pernos con resalto, 3/8 - 16 Tuerca Bande en 2- Tuercas hexagonales, 3/8 - 16...
  • Page 37: Instalación

    INSTALACIÓN Asegúrese de que el tomacorriente que CÓMO PREPARAR LA UNIDAD será utilizado tenga la misma Ubicación del compresor de aire configuración que el enchufe de conexión Ubique al compresor de aire en una zona a tierra. NO UTILICE UN limpia, seca y bien ventilada.
  • Page 38 Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al cuadro de de extensión eléctrica originará una caída especificaciones.
  • Page 39: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 40 Válvula reguladora: Cuando el Protección para sobrecarga del motor: compresor de El motor tiene un protector de sobrecarga aire se térmico de reposición automática. Si el encuentra motor se sobrecalienta por alguna razón, funcionando, la el protector de sobrecarga apagará el válvula motor.
  • Page 41 3. Abra completamente la válvula de drenaje Cómo poner en marcha: (sentido antihorario) a fin de permitir la Mueva la palanca On/Auto/Off a la salida del aire e impedir el aumento de la posición "AUTO" y deje que se presión dentro del tanque de aire durante incremente la presión del tanque.
  • Page 42: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Cada Diariamente Cada Anualmente o luego de de cada cada uso horas horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 43 Una vez drenada el agua, cierre la Si está sucio enjuague el filtro de aire válvula de drenaje (girando en con agua tibia y exprímalo hasta que sentido horario). Ahora el compresor seque. de aire podrá ser guardado. Reponga el filtro de aire y su retén. NOTA: Si el filtro de aire está...
  • Page 44: Servicios Y Regulaciones

    SERVICIO Y AJUSTES La unidad cicla Tubo de Tuerca automáticamente salida en cuanto la energía eléctrica es Tubo aliviador conectada. Al efectuar el mantenimiento, usted quedará expuesto a tensión viva, de presión Válvula aire comprimido o partes en movimiento. reguladora Debido a tales circunstancias, podrían ocurrirle lesiones personales.
  • Page 45 12. Vuelva a instalar la tubería de salida y Extraiga el regulator. ajuste las tuercas. Aplique sellador para caños al niple. 13. Reponga el recubrimiento y la Ensamble el regulador y oriéntelo tal consola. como se indica. 14. Ejecute el procedimiento de puesta en marcha.
  • Page 46: Almacenaje

    ALMACENAJE El agua se Antes de guardar su compresor de aire, condensa dentro asegúrese de hacer lo siguiente: del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando la paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes.
  • Page 47: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 48 PROBLEMA CAUSA CORRECCIÓN Si hubiese una caída excesiva de Es normal que ocurra algún La lectura de la presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección Operación.
  • Page 49 CAUSA PROBLEMA CORRECCIÓN El motor no Deje enfriar el motor y el El interruptor de protección des interruptor de sobrecarga se funciona. obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 50: Notes/Notas

    NOTES/NOTAS 50- SP D27221...
  • Page 51: Notes/Notas

    NOTES/NOTAS 51- SP D27221...
  • Page 52 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.

This manual is also suitable for:

919.167340919.165521

Table of Contents