Craftsman 919.167241 Owner's Manual

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.167241:

Advertisement

Available languages

Available languages

Owner's Manual
JCRRFTSMRN1
Permanently
Lubricated
Tank Mounted
AIR COMPRESSOR
Model No.
919.167241
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D29408
Revl
8/15/03

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.167241

  • Page 1 Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D29408 Revl 8/15/03...
  • Page 2: Table Of Contents

    HOW TO ORDER REPAIR PARTS ...... back cover FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
  • Page 3 Model No. 919-167241 Max. Developed HP Bore 1.875" Stroke 1.25" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig E.'ff.,1 =l_lk'd [=-ll]lm]::lmll_l::[,."]m m] = l=ll_l i ll [o _]_: "] This manual contains information that is important for you to know and understand.
  • Page 4 I1_I_o];]lL"_ +Ill [,,'9'-'I _1 _ i'dl I +F,,,_11_o _+]L_,[,,I Save these instructions improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. ,I;1"1.,I;I n WARNING: Risk of explosion or fire How To Prevent It What Could Happen...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen Failure to properly drain Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with it may cause electric shock,...
  • Page 7 :f:_rJ:!;I I WARNING: Risk of Burns WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts compressor head or outlet tubes, can on compressor during or immediately result in serious burns, after operation.
  • Page 8 WARNING: Risk or Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) WHAT CAN HAPPEN HOW TO PREVENT IT Oil can leak or spill and could result in Always place compressor on a fire or breathing hazard; serious injury or protective mat when transporting death can result.
  • Page 9: Duty Cycle

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Contents of Carton It will be necessary to brace or support Air Compressor one side of the outfit when Wheels installing the wheels because the Shoulder Bolts, 3/8-16 compressor will have a tendency to tip over. Hex Nuts, 3/8-16 Install one shoulder bolt and one Molded Foot Bumpers nut for each wheel.
  • Page 11 HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration dry and well ventilated area.
  • Page 12: Operation

    Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 13 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. On/Auto/Off Pressure Switch Switch Outlet...
  • Page 14 Drain Valve: The drain valve is Before Starting located at the base of the air tank Break-in Procedure and is used to drain condensation the end of each use. _Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not closely followed.
  • Page 15 How to Start: Before Each Start-Up: Place On/Auto/Off lever to Turn the On/Auto/Off lever to "AUTO" and allow tank pressure "OFF" and close air regulator. to build. Motor will stop when Pull regulator knob out, turn tank pressure reaches "cut-out" counter-clockwise until it stops.
  • Page 16 Customer Responsibilities Before Daily or each after each 2,heck Safety Valve • )rain Tank • To Drain Tank Risk of Unsafe Operation. Unit Set the On/Auto/Off lever to cycles automatically when power is "OFF" and unplug unit. on. When servicing, you may be Pull the regulator knob out and exposed to voltage sources, turn counterclockwise...
  • Page 17: Maintenance

    All maintenance and repair Unscrew the check valve (turn operations not listed must be counterclockwise) using a socket performed by Trained Service wrench. Technician. Make sure the valve disc moves freely inside the check valve and Risk of Unsafe the spring holds the disc in the Operation.
  • Page 18 NOTE: Arrow indicates flow of air. To Replace Regulator Make sure it is pointing in the Release all air pressure from air direction of air flow. tank. See "To Drain Tank" in the Maintenance section. Regulator Set the On/Auto/Off lever to "OFF"...
  • Page 19 d:TollJ :] l ::_-'_ - " [oIo_ | I _[_ Risk of Unsafer Operation. Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated 3ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 21 PROBLEM CAUSE CORRECTION Motor will not Check fuse box for blown Fuse blown, circuit breaker run. tripped. fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
  • Page 22 ._ I-'I_o]_V_l ".I -'! _o] -II m] ¥,___,__ _ v Air Compressor Model Number 919.167241 were built with a check valve and bushing reducer. If check valve * IMPORTANT= Some models needs to be replaced, remove the old check valve and reducer bushing before replacing with the preferred one piece check valve (Key 18).
  • Page 23 Check Valve D20114 Safety Valve CAC-1254 Isolator (4) LA-3027 Label -- Drain Tank LA-3266 Label -- Warning LA-3069 Label -- Craftsman D24202 Label -- Performance SSF-621 Screw, 8-18 x .626 (2) D23627 Label -- Tool Application D25730 Grip SS-1286 Nipple, 1/4-18 NPT X .88...
  • Page 24 Air Compressor Model Number 919.167241 The picture shown is for reference only. It may differ from actual unit. 18 / Torque D29408 24_ENG...
  • Page 25 Air Compressor Model Number 919.167241 Part Number Description • SSG-8169 "O" Ring Screw 3/8-16 UNC Hex SSF-3147 > ..Rod Assembly Z-D23625 Endbell Assembly D25735 Shroud (left) • CAC-1212 Tube Seal AC-0206 Tube Isolator SSF-3156 Shroud Screws 10-9 x .50 (5) SUDL-9-1 Screw 8-32 x .375/.344 •...
  • Page 26 GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opei6n, Io reparar& o reemplazar& sin eosto alguno.
  • Page 27 Modelo N ° 919-167241 Max. HP desarrollado Di&metro interior 1,875" _7,6 ram) Carrera 1,25" _1,6 mm) 120V Tensibn monofasica Circuito mfnimo requerido Tipo de fusibleAccibn retardada Capacidad de aire en el tanque 15 Galones (56,8 litros) Presibn de corte de entrada Presibn de corte de salida SCFM a 40 psig 4,9 Calibre de libras...
  • Page 28 GUARDE ESTAS INSTRUCCIONES La operaciSn o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y dafios a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. ',]=lm [_ ;{_ ADVERTENCIA: Riesgo de Explosi6n o Incendio qud puede...
  • Page 29 '.t=1![_ ;{q F 3%q ADVERTENCIA: Riesgo de Explosibn las siguientes condiciones podrian, causar el debilitamiento del tanque, determinar su explosion violenta, daSos a la propiedad o serias lesiones. qu_ puede occurrir c6mo prevenido 1. Drenaje inadecuado del agua Drene el tanque diariamente o despu_s de condensada...
  • Page 30 •,,l ::1 n nl [_1r,{q ADVERTENCIA: Riesgo de Descarga Eldctrica qud puede occurrir cbmo prevenirlo Su compresor de aire estA accionado pc# Janl&s opere el compresor a la intemperie electricidad. Como cua_quier otto dispositivo cuando est& I_oviendo o en condiciones el_ctrico imputsado et6ctricamente,...
  • Page 31 ADVERTENCIA: Riesgo de Quemaduras qu_ puede occurrir c6mo prevenido Jam&s toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente despu_s del compresor o los tubos de salida del de la operaci6n, el compresor permanecerd escape, puede ocasionarle...
  • Page 32 ADVERTENCIA: Riesgo de Serias Lesiones o Da_os a la Propiedad Transportar el Compresor (Fuego, inhalacibn, da_o a la superficie de vehlculos) qud puede occurrir c6mo prevenido El aceite puede derramarse y e_lo podr{a Deposite el compresor sobre una atfombrilla resultar en serias lesiones o la muerte debido protectora cuando Io transporte= a fin de...
  • Page 33 Presibn minima de torte: Cuando el Familiaricese con los siguientes terminos, motor est& apagado, la presion del tanque antes de operar la unidad: de aire baja a medida que usted continua CFM: (Cubic feet per minute) Pies cQbicos usodo su aceesorio. Cuando la presion pot minuto.
  • Page 34 Contenido del embalaje Compresor de aire un lado del equipo euando se instalen Ruedas las ruedas porque el compresor tendra tendencia a volcarse. Bulones de tope, 3/8 - 16 Instale un balon de tope y una tuerca Tuerca hexagonal, 3/8 - 16 por cada rued&...
  • Page 35 COMO PREPARAR LA UNIDAD AsegQrese de que el tomacome_te que sera utilizado tenga la misma Ubicaci6n del compresor de aire con_uraci6n que el enchufe de coneyJ6n atierr& NO UTILtCE UN Ubique al compresor de aire en una zona ADAPTADOR. Var figura. limpia, seca y bien ventilada.
  • Page 36 Cables de extensibn eldctrica Proteccibn del voltaje y del circuito No se recomienda la utilizacion de cables Acerca del voltaje y la minima cantidad de de extensi6n el_ctrica. El uso de cables circuitos requeridos, refierase al cuadro de de extensi6n el_ctrica originar& una caida especificaeiones.
  • Page 37 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 38 Valvula de drenaje: La valvula de drenaje Antes de poner en marcha se encuentra ubicada sobre la base del Procedimiento para el asentamiento tanque de sire y se usa para drenar la condensaci6n al fin de cads uso Riesgo de Operaci6n Insegura.
  • Page 39 Antes de cada puesta en marcha: Cbmo porter en marcha: Coloque el interruptor On/Auto/Off en la Mueva la palanca On/Auto/Off a la posici6n "OFF" y cierre el regulador de posici6n "AUTO" y deje que se aire. incrementela presi6n del tanque. El motor se detendr_ una vez alcanzado el Tire de la perilla del regulador, gire en valor de presi6n "de corte"...
  • Page 40 Responsabilidades del cliente Antes _iadamente cada )luego d e :ada uso /erifique {a valvula de seguridad • )renaje del tanque • Cbmo drenar el tanque Riesgo de Operaci6n Apagar la unidad co{ocando el Insegura: La unidad arranca interruptor en On/Auto/OFF automaticamente cuando estd "OFF".
  • Page 41 Desenrosque la vAIvula regu_adora(gire en sentido antihorario) utilizando una en cuanto la energla eldctrica es Ilave tubular. conectada. AI efectuar Asegt_rese que el disco de la va_vula se mantenimiento, usted quedara mueva _ibremente dentro de la valvu_a expuesto a tensibn viva, aire comprimido o partes en movimiento.
  • Page 42 NOTA: La flecha indica el sentido del Para reemplazar el regulador flujo del aire. AsegQrese que este apuntando a la direcci6n en la que fluye Libere toda la presion del aire del el aire. tanque Vea "Drenaje del tanque" en la secci6n "Mantenimiento ".
  • Page 43 Antes de guardar su compresor de aire, Riesgo de asegQrese de hacer Io siguiente: Explosibn. El agua se condensa dentro del tanque de Revise la secci6n "Mantenimiento" aire. Si no se drena, ella de las p&ginas precedentes y ejecute el mantenimiento programado corroera debilitando la paredes del...
  • Page 44 [_l_.,_ Im] _ I m] p ';l_] Z [T_--]lli[o,,[o] I m] " _ I _ :To]=]nil = 1 i_Y;%,."] Riesgo de Operacibn Insegura: La unidad arranca automaticamente cuando esta enchufade. AI hacer el mantenimiento, el operador puede queder expuesto a fuentes de corriente y de aire comprimido o e piezas movibles.
  • Page 45 PROBLEMA CORRECCI(_N CAUSA Si habiese una cafda excesiva de La lectura de la Es normal que ocurra algen presi6n durante el uso del descenso en la presion. presion sobre an accesorio, aiaste el regulador man6metro acuerdo alas instrucciones de ]a viene equipado seccion Operacion<...
  • Page 46 CORRECCI6N PROBLEMA CAUSA El motor no Fusiblefundido;interrLiptor Verifique la caja de fusibles observando funciona. autom&tico del circuitodisparado, la existencia de fusibtes fundidos y sustitQyalos en caso de necesidad, Restablezca el interrLiptoraLitomatico, NOuse un fusible o interruptorautom@_co con valoresque excedan los especificados para la rama de su circuito.
  • Page 47: Repair Protection Agreements

    Agreements Reparaciones Congratulations on making a smart Felicitaciones por hacer una compra purchase. Your new Craftsman <_' product is inteligente, Su nueva unidad Craftsmaq _ est& designed and manufactured for years of disefiada y tabricada para afios de operaci6n dependable operation.
  • Page 48 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself.