Clearance To Combustibles - Lennox EVB125 Installation Instructions Manual

Elite series b-vent gas fireplace heater insert
Table of Contents

Advertisement

MINIMUM CLEARANCES TO COMBUSTIBLES
MODELS: EBVI25 & EBVI30
These appliances can be installed in most residential fi replace
confi gurations. If installed close to an adjacent wall, ensure that
the minimum clearances to combustible surfaces are maintained.
A local building inspector should review your plans prior to
installation.
Refer to Figures 3, 4a, 4b and 6 for Clearances to Combustibles.
Minimum clearances include spacers/standoffs or surfaces to
combustible construction.
Notes for Table 5:
*
This includes any projections such as shelves, window
sills, mantels, spacers/standoffs or surfaces to combustible
construction etc. above the appliance. Paint or lacquer used
to fi nish the mantel must be heat resistant in order to avoid
discoloration.
** If hearth is elevated, subtract 1 inch of hearth extension
required for every 2 inches of height (see Figure 6).
Clearances
Side
A
Wall
Figure 3
Mantel Clearance, Model: EBVI30: The
mantel should be located in the shaded
area (light gray) shown below.
D
18"
17"
16"
15"
C
14"
0
12
10
8
6
4
11
9
7
5
Top of Insert
Side View
(see "C" on Fig. 3)
Figure 4a
Mantel
G
Hearth Protection
Mantel Clearance, Model: EBVI25: The
mantel should be located in the shaded
area (light gray) shown below.
15 1/2"
13"
11"
C
8 1/2"
0
12"
2
0
3
1
Side View
Figure 4b
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Clearances to
Combustibles
A
Side Wall
B
Ceiling or Alcove Height
C*
Mantel Height
D*
Mantel Projection from
Wall
E
Clearance to Floor
F**
Hearth Protection
(from Fireplace Face)
G
Hearth Protection
Width
H
Alcove Width
I
Alcove Depth
Table 5
Alcove Minimum Width: The specifi ed minimum width of the
alcove cannot be reduced with the use of wall protection.
Ceiling (or)
Alcove Height
Top View
Alcove
C
Top of Insert
B
I
E
Figure 5
D
0
5"
1"
8"
Top of Insert louver
(see "C" on Fig. 3)
Inches (millimeters)
EBVI25
EBVI30
8" (203 mm)
8" (203 mm)
64" (1626 mm) 64" (1626 mm)
See Fig. 4b
See Fig. 4a
See Fig. 4b
See Fig. 4a
0" (0 mm)
0" (0 mm)
**16" (406 mm) **16" (406 mm)
44" (1118 mm) 40" (1016 mm)
45" (1143 mm) 48" (1219 mm)
36" (914 mm)
36" (914 mm)
Fireplace
Insert
Hearth
H
Hearth Protection: For every 2" of hearth height,
subtract 1" of hearth extension required.
Side View
of Insert
F
Existing Fireplace Hearth
16"
2"
4"
15"
14"
13 1/2"
At 7" hearth height, no hearth extension is required
Figure 6
Min./Max.
Min.
Min.
Min.
Min.
MAX.
Min.
Min.
Min.
MAX.
6"
7"
7

Hide quick links: