Gas Specifications; Gas Inlet & Manifold Pressures; High Elevations; Valve Access - Majestic fireplaces ODGSR36A Homeowner's Installation And Operating Manual

Outdoor gas fireplace
Table of Contents

Advertisement

Gas Specification
Model
Fuel Gas Control
ODGSR36ARN
Nat.
ODGSR36ARP
Prop.
ODGSR42ARN
Nat.
ODGSR42ARP
Prop.
Gas Inlet & Manifold Pressures
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
ODGSR36A / ODGSR42A
Certified to
CSA 4-96
Units: G01AU6, G01BU6, G01AU2, G01BU2

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370 m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is rec-
ommended for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.

Valve Access

Valve access can be accomplished in one of two ways:
1. Remove the front panel just below the front of the
hearth pan. This is accomplished by lifting on the
panel. To replace the valve access panel line up the
two pins with the holes in the surround bottom and
push the panel over the front of the hearth pan. (Fig.
5)
2. Lift the brick with the Majestic logo on it. (Fig. 6)
20007114
Max.
Min.
Input
Input
Millivolt Hi/Lo
60,000 42,600
Millivolt Hi/Lo
60,000 44,000
Millivolt Hi/Lo
60,000 42,600
Millivolt Hi/Lo
60,000 44,000
Natural
LP
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5"w.c.
10.0" w.c.
ODGSR Series Outdoor Gas Fireplace
Fig. 5 Valve access.
Fig. 6 Lift brick with logo on it to access valve.
FP1415
lift brick access
11/24/03 djt
Hard, Flat Surface
(i.e. concrete)
Fig. 7 Exterior chase installation.
FP1642a
concrete install
9/06
FP1414
FP1414
ODUVSR
valve access
11/24/03 djt
Majestic Logo
Brick
FP1415
NOTE: When installation is
on a hard, flat surface (such
as concrete), the surface
must be sloped 1/4" per foot
away from any structure.
Blocking
1/2" (13 mm)
FP1642a
7