Checking for Other Electrical Problems in Single-phase Motors
This section provides procedures for checking the components such as the thermal pro-
tector, relay and capacitor in a single-phase compressor. Table 4-3 (below) can be used
to locate the appropriate procedure for the compressor you are servicing. Examine the
compressor and determine presence and/or the type of:
• Thermal protector (internal or external)
• Relay (current, potential or PTC)
• Capacitor(s) (start or run)
With that information, use Table 4-3 to determine the location of the procedure for the
compressor you are servicing.
For more information on:
• Compressor motor types, see "Single-phase Compressor Motor Types" on pages 16-
17.
• Thermal protectors, see "Hermetic Compressor Thermal Protectors" on page 19.
• Starting relays, see "Compressor Motor Starting Relays" on pages 21-24.
• Capacitors, see "Selecting Capacitors" on pages 24-26.
Table 4-3: Locating Service Procedures by Component Types
Thermal Protector
Compressor Motor
Type
Internal
Resistance Start In-
duction Run (RSIR)
(Split-Phase)
Capacitor Start In-
duction Run (CSIR)
Capacitor Start and
Run (CSR)
Permanent Split
Capacitor (PSC)
If your compressor has:
Type
External
Current
Relay Type
Capacitor Type
Potential
PTC
WIRED
MODULE
WIRED
MODULE
Go To:
Page
Run
Start
44
46
48
50
53
56
59
62
64
66
68
43