Troubleshooting - Weil-McLain CGA 2 Series Installation And Maintenance Manual

Gas-fired water boilers
Hide thumbs Also See for CGA 2 Series:
Table of Contents

Advertisement

CGa Series 2 Gas-Fired Water Boiler -
Boiler Manual
11
b
Troubleshooting - spark-pilot boilers
NOTICE
The information on this page
and
pages 50 through 56
apply
only
to
spark -ignited pilot CGa
boilers.
These boilers are equipped with
an ignition control
module
that
has indicator lights
to show control
status.
Charts
1
through
6
, pages
51-56,
help
you
identify
problems
based on
indicator
light
condi-
tions.
Figure 29
CGa
Ignition
control
module
Control module
!A
WARNING!
NOTICE
Solder
o
r water
splatter be-
tween plugs and
circuit
board
can cause improper operation of
control
module. Place
a
shield over
the
boiler
internal controls and
components
during installation.
Failure
to
comply
could result in
severe personal injury,
death
or
substantial property
dan1age.
Make
sure
grou nd wiring
is in-
stalled per
wiring
diagran1.
Good
groundU1g
is
extremely important
for proper operation.
Part Number
550·142·
779/0712
Control indicator lights -
HARD
LOCKOUT
Summary
(Flashing
LED's)
MAY
remove 120VAC power
for
more than 2 seconds
to
clear
lockout
OR
ignition
control
Will
automatically
restart
sequence of
operation after
1
hour
waiting
period
after
fault
condition
is
cleared.
INDICATOR LIGHT
POWER
Flashes
once
per
second
Flash
code 2*
Flash
code 3*
Flash
code 4*
CONDITION
120 VAC connection to
boiler
reversed.
Internal
fault,
microprocessor
or
rnemol)'
.
Unused.
Unused.
Flash
code
s•
Internal
fault,
water
thermistors
disagree.
Flash
code
6*
Internal
fault,
gas
valve
circuit.
Rash code
pattern:
POWER
LED
flashes
2,
3, etc. times rapidly
followed
by 2
seconds
off,
then
repeats.
ALL LED'S FLASHING
(Propane
Gas
Only)
Failure
to establish
pilot
name after
4
attempts.
Follow Manual
Reset
Procedure on
pages
34
&
35 to conect.
SOFT LOCKOUT Summary (Flashing LED's)
MAY
remove 120VAC power
for
more
than
2
seconds,
cycle
thermostat
for
between
2
and 20
seconds,
OR
ignition control
Will automatically
restart
sequence
of
operation
after 1
hour
waiting
period.
INDICATOR LIGHT
CONDITION
POWER+
TSTAT/CIRC
POWER
+ DAMPER
POWER
+
FLAME
High
voltage
detected
on
TSTAT circuit.
Damper
stuck closed or unable
to
close end
switch
within
45
seconds
from
TSAT
call.
Flame
sensed without
call
for
heat
or out
of
sequence
during
ignition
trial.
CAUTION Summary (Flashing
LED's)
INDICATOR LIGHT
DAMPER
LIMIT
FLAME
CONDITION
Damper end
switch
opened
after
it
had been
proven
closed.
FatJl detected
in
temperature sensing
hardWare.
Flame loss
or
ftame
not
sensed
during
trial
for ignition.
Troubleshooting
the
control
module
See
Fig
ure
3
0,
page 50, for location of harness
plug
receptacles and
plugs
on
the
control
module.
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cga-25Cga-3Cga-4Cga-5Cga-6Cga-7 ... Show all

Table of Contents