Boiler Economy Setting - Weil-McLain CGA 2 Series Installation And Maintenance Manual

Gas-fired water boilers
Hide thumbs Also See for CGA 2 Series:
Table of Contents

Advertisement

COa Series 2 Gas-Fired Water Boiler -
Boiler Manual
6b
Start-up - operate boiler
IAWARNINGI
DO
NOT
proceed
with
boiler operation unless boiler and system have been filled with water
and all
instructions and
procedures of previous
manual sections have been completed. Failure
to do
so
could
result
in severe personal
injury, death
or
su
bstantial property damage. Before
starting
the boiler, do the following:
Read manual
Section 9
and
the
Operating
Ins
truction
procedure
(see
Table
5, below).
Verify the boiler and system are
full of
water.
Verify the
Start-up preparation
procedures of
Section
6 have been completed.
Table 5
Operating
instruction location
guide
Models
Spark~gnlted
pilot
Gas
Page
CGa-25
Honeywell
VR8200NR8300
Natura.L!Propane
38
to
Robet1shaw
7200
Natural
39
CGa-6
White-Rodgers
36E
Natural
40
CGa-7
Honeywell
VR8200NR8300
Natural/Propane
38
&
CGa-8
White-Rodgers
36C
Adjust boiler control settings
BOILER OPERATING TEMPERATURE
With power turned on,
control module
receives
a
signal
from
the
temperature sensor and
displays
boiler
temperature.
The
control knob labeled
BO
ILER TEMP
is used
to adjust
the
operating temperature setpoint, turning
clockwise
to
increase
temperature
setting
and counterclockwise to decrease. \¥hen
the
knob
is
turned
to
adjust
temperature
the
display
wiU brighten to
indicate
adjustment
mode.
After
temperature
is
set
to desired
value, display
wiU
dim
after approximately 5 seconds to
indicate
measurement mode.
ADJUST BOILER OPERATING TEMPERATURE
TO
DESIRED SETPOINT.
BOILER ECONOMY
SETTING
To comply
with
Department of Energy
regulations,
the
control
module
circulates
available hot water before
turning
on the boiler
to attempt to
satisfy a
caU
for heat \¥hile
attempting
to satisfy
the heat
demand,
the
control
module
also
monitors
the boiler
temperature changes
via the
temperature
sensor and
determines
whether or
not the available hot
water will satisfy the demand,
adjusting
the time
delay
to
turn on
the
boiler until
it determines
that
additional
heat will be needed. TI1e knob labeled ECONOMY
ADJUST provides
an
adj
ustment between maximize
(MAX) and
minimize (MIN) the delay. The maximum
(MAX)
adj
ustment
position should
be
used
to maximize
energy savings. Turning the
knob
counterclockwise
decreases
the delay
time and
should only
be used in the event that the heated
space
becomes uncomfortable.
30
ADJUST ECONOMY TO DESIRED POSITION (MAX IS
THE
PREFERRED
SETTING).
N atural
41
IMPORTANT
In
accordance with Section
325 (f) (3)
of the Energy Policy and
Conservation Act, this boiler
is
equipped with a feature
that
saves
energy
by
reducin~
the boiler water
temperature
as
the heating
load decreases. This
feature
is
equipped
with
an override which
is
provided primarily
to
permit
the
use of an external energy
management
system that serves the same function.
THIS
OVERRIDE
MUST NOT BE
USED
UNLESS AT
LEAST
ONE OF THE FOLWVliNG
CONDITIONS
IS TRUE:
An external energy
management
system is
installed that
reduces the boiler water
temperature
as
the
heating
load
decreases.
This boiler
is
part of a modular or multiple
boiler system
having
a
total
input of
300,000 BTU/hr or greater.
This boiler is equipped with a tankless
coil.
Part
Number