Features

ELECTRONIC CONTROL

INSTRUCTIONS
POWER button
1
Turns power on/off.
2
SLEEP button
Used to initiate the SLEEP operation.
3
FAN button
Controls the fan speed. Press to toggle between three fan speeds: LOW
(press 1 time), MEDIUM (press 2 times) and HIGH (press 3 times). The
fan speed indicator light indicates the corresponding fan setting. Press the
button a fourth time to initiate AUTO-FAN mode. In this mode, all three
indicator lights will light up.
4
UP and DOWN buttons
Used to adjust (increase /decrease) temperature settings (1°C/2°F
increments) in a range of 17°C(62°F) to 30°C(86°F) or the TIMER set-
ting in a range of 0~24hrs. The control is capable of displaying
temperature in degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and Down buttons at the
same time for 3 seconds.
MODE select button
5
Selects the appropriate operating mode. Each time you press the but-
ton, a mode is selected in a sequence that goes from AUTO, COOL,
DRY, FAN and HEAT(select models only). The mode indicator light
illuminates depending on the mode settings.
TIMER button
6
Used to initiate the AUTO ON start time and AUTO OFF stop time pro-
gram, in conjuction with the UP and DOWN buttons.
SWING button
7
Used to initiate the Auto swing feature. When operating press the
SWING button to stop the louver at the desired angle.
8
LED DISPLAY
Shows the set temperature in °C or °F and the Auto-timer settings.
While on DRY and FAN modes, it shows the room temperature.
Error codes:
E1 - Room temperature sensor error-Unplug the unit and plug
it back in. If error repeats, call for service.
E2 - Evaporator temperature sensor error- Unplug the unit and
plug it back in. If error repeats, call for service.
E3 - Condenser temperature error - Unplug the unit and plug it
back in. If error repeats call for service.
E4 - Display panel communication error - Unplug the unit and
plug it back in. If error repeats call for service.
P1 - Bottom tray is full - Connect the drain hose and drain the
collected water away. If error repeats, call for service.