Water Drainage - Danby DPA120B1WB Owner's Use And Care Manual

Danby portable air conditioner owner's use and care guide
Hide thumbs Also See for DPA120B1WB:
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions

WATER DRAINAGE

Fig.22
Remove the
upper drain
plug
• During dehumidifying modes, remove the upper drain plug from the
back of the unit, install the drain connector (5/8" universal female con-
necter) with 3/4" hose (not included). For the models without a drain con-
nector, just attach the drain hose to the hole. Place the open end of the
hose directly over the drain area in your basement floor. Please refer to
Fig.22.
During heating pump mode, remove the lower drain plug from the back of
the unit, install the drain connector(5/8 universal female connector) with
3/4 hose (not included). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of the hose directly
over the drain area in your basement floor. Please refer to Fig.23.
• When the water level of the bottom tray reaches a predetermined level,
the unit beeps 8 times, the digital display area shows P1. At this time
the air conditioning/dehumidification process will immediately stop.
However, the fan motor will continue to operate (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug
and let the water drain away (Fig.24). Restart the machine until the P1
symbol disappears. If the error repeats, call for service.
NOTE: When operating or draining water always protect carpeting or
floors from possible water spillage.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Fig.23
Continuous
drain hose
Remove the
lower drain
plug
14
Fig.24
Continuous
drain hose

Hide quick links: