Jøtul Wood Stove Installation And Operating Instructions Manual page 24

Jotul f 602 usa-2 wood stove operating manual
Table of Contents

Advertisement

Available languages

Available languages

Fig. 17
Parallel installation in a corner with
wall shield
Wall shield
• Must be 1" off the
wall and 1" off the
floor.
• With single wall
pipe, the shield
must be 49" high
measured off the
floor.
• With double wall
pipe, the shield
must be 37" high
measured off the
floor.
• Both shields MUST
extend and join in
the corner.
Corner installation with wall shield
Fig. 18
Wall shield
• Must be 1" off
the wall and 1"
off the floor.
• With single wall
pipe, the shield
must be 49".
• With the double
wall pipe, the
shield must be
37" high.
• Both shields
MUST extend
and join in the
corner.
Fig. 19
A
A: Lift to open
B: Left - closed, Right - open
(Measurements in cm - for Canada)
24
Combustible wall
The wall
shield must
extend a
minimum of
4" (102 mm)
past the side
of the stove
The wall shield must extend a
minimum of 7" (178mm) past the
ash lip of the stove
Combustible wall
The wall shield
must extend a
minimum of 7"
(178mm) past
the front
corner of the
stove.
The wall shield must
extend a minimum of 7"
(178mm) past the front
corner of the stove.
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F 602F 602 usa

Table of Contents