Model BK Installation
1.
Be certain that all wire terminals are
securely attached to terminals on blower
motor and that the screw retaining the
green ground wire is tight (see Figure 14).
2.
Place blower against lower rear wall of
firebox outer wrapper with exhaust port
directed upward. Depending on your
model, you may have to carefully route
the blower assembly past controls and
brackets and position blower inside
back opening. The blower will be held in
position against the back wall by magnets
incorporated onto blower housing (see
Figure 14).
Spade
Terminals
Green
Ground
Wire
Screw
Side View
Blower
Firebox Bottom
Installed
After
Lower
Panel
Removed
Figure 14 - Blower Model BK
3.
Using pliers, remove lock nut from speed
control by turning counter clockwise.
Mount speed control box by placing
plastic control shaft through hole on left
or right side of the firebox hearth by slid-
ing control box down through large hole
in firebox bottom and up through hole
(see Figure 15). Secure speed control to
firebox hearth with previously removed
lock nut with pliers by pushing and turn-
ing lock nut until it is tight against firebox
hearth of fireplace (see Figure 15).
14
INSTALLATION
Continued
Magnetic Strips
Exhaust
Port
Air Flow
Direction
Blower
Location Magnets
www.SuperiorFireplaces.US.com
CAUTION: Use gloves as
sheet metal parts may be sharp.
Control
Knob
Figure 15 -Attaching Speed Control
(Model May Vary From Illustration)
4.
Check to make sure power cord is com-
pletely clear of blower wheel and there
are no foreign objects in blower wheel.
Also, double check all wire leads and
make sure wire routing is not pinched
or in a precarious position. Correct ac-
cordingly.
Lock
Nut
Control
Shaft
Firebox
Hearth
126715-01A