There must be no end play or binds in feed rock shaft (C).
Check:
1. Remove the free arm extension table, bed bottom cover and extension table bottom
cover.
2. Move feed rock shaft (C) left to right to check for end play.
Adjustment:
1. Hold feed rock shaft (C) to the left against rock shaft center (B) and check that the feed
dog is centralized in the needle plate slots.
2. Loosen left center clamp screw (A) and move center (B) with rock shaft (C) left or right
to centralize feed dog in needle plate slots.
3. Tighten left center clamp screw (A).
4. Loosen the right center clamp screw (F).
5. Move the right rock shaft center (E) to the left against rock shaft (C) and tighten clamp
screw (F).
Rev. n .
o
Feed Rock Shaft End Play
91
358487-001