11 Measurements and Adjustments

11.1. The Setting Method of JIG (Base Unit)

11.1.1. Preparation
11.1.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.1.1.2. JIG and PC
• EEPROM serial JIG
JIG Cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PQZZTG7100E
11.1.2. PC Setting
11.1.2.1. Connections
Connect the AC adaptor to CN2 (base unit).
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
KX-TG7100ES/KX-TG7102ES/KX-TG7103ES/KX-TGA710ES
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
Resistor
R2
R3
R4
R7
47
Old value (kΩ)
New value (kΩ)
22
3.3
22
3.3
22
4.7
4.7
10