Honeywell AlarmNet 7845GSM Installation And Setup Manual page 27

Digital cellular communicator
Hide thumbs Also See for AlarmNet 7845GSM:
Table of Contents

Advertisement

PROMPTS
Telco Zone
25
(0)_
Open/Close Zone
26
(0)_
Zn1 Trigger Type
27
(V+)_
Restore Zn1 Y/N
28
(Y)_
Delay Zn1 (secs)
29
(00)_
Rpt Zn1 ONLY if
30
Armed (N)_
Invert Zn2 Y/N
31
(N)_
WWW.DIYALARMFORUM.COM
ZONE
4204/
ENTRY
TRIG.
2-4204
WWW.DIYALARMFORUM.COM
Section 3: Programming the 7845GSM
OPTIONS
See "Important Information Regarding Zone
Zone Trig: [3-7]
Input Options" on previous page.
4204: [1-4]
Enter the zone number to be used for telco line
fault reports. This zone assignment must be
2-4204: [1-8]
unique from the open/close zone selected in
[0] = not used
Prompt 26.
Zone Trigger Mode: If any zone is
programmed for "report only if armed," zone 7
cannot be used. If Lynx Panic is enabled, zone
3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used
as a telco zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper reporting
is enabled, zone 8 cannot be used.
NOTE: Connect the telco line fault output (or
relay output programmed for "telco line fault") to
the telco zone.
Enter the zone number to be used for open/close
Zone Trig: [3-7]
(arm/disarm) reports. This zone assignment
4204 : [1-4]
must be unique from the telco zone selected in
Prompt 25.
2-4204: [1-8]
Zone Trigger Mode: If any zone is
[0] = not used
programmed for "report only if armed," zone 7
cannot be used. If Lynx Panic is enabled, zone
3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used
as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Enables restore reporting for zone 1.
[01-15]
Defines the reporting delay in seconds for zone 1.
[00] = no delay
[Y], [N]
Reports alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 1.
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
DESCRIPTION