Goodman GME8 Technical Manual page 5

33-3/8" 80% gas furnace upflow/horizontal
Table of Contents

Advertisement

PRODUCT DESIGN
Accessibility Clearances (Minimum)
Unobstructed front clearanace of 24" for servicing is rec-
ommended.
Top clearance for horizontal confirguration - 1"
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHES
Sides
Rear
Front
1
0
3
Approved for line contact in the horizontal postion.
* 24" clearance for serviceability recommended.
** Single Wall Vent (SW) to be used only as a connector.
Refer to venting tables outlined in the installation manual for
additional venting requirements.
24" at front is required for servicing or cleaning.
Note: In all cases accessibility clearance shall take prece-
dence over clearances from the enclosure where accessibil-
ity clearances are greater. All dimensions are given in inches.
Vent
Bottom
Top
SW
B
C
6
1
High Altitude Derate
IMPORTANT NOTE: The furnace as shipped requires no
change to run between 0 - 4500 feet. Do not attempt to
increase the firing rate by changing orifices or increasing
the manifold pressure below 4500 feet. This can cause poor
combustion and equipment failure.
High altitude installations above 4500 feet may require both
a pressure switch and an orifice change. These changes
are necessary to compensate for the natural reduction in
1
the density of both the gas fuel and the combustion air at
higher altitude.
For installations above 4500 feet, please refer to your dis-
tributor for required kit(s). Contact the distributor for a tabular
listing of appropriate manufacturer's kits for propane gas
and/or high altitude installations. The indicated kits must be
used to insure safe and proper furnace operation. All con-
versions must be performed by a qualified installer, or ser-
vice agency.