The 6 hardwired zones on board may be eliminated from the system to use an all-wireless system that
supports up to 24 zones. The system can be programmed without skips in zone usage by assigning an
offset to the first RF zone (Submode 2, Question 50, L1 and L2). For example, if 14 hardwired zones
are used (6 on board and 8 on the hardwired expander), the offset may be set to 15 to start the usage of
wireless points. The default value for the wireless offset is 07.
The following chart lists the most popular compatible wireless devices by market. Please consult your
distributor for the availability of additional products.
Device
2-Zone Transmitter
Dual Element PIR
Panic Transmitter
Smoke Detector
4-Button Keyfob
NOTE: This security system is not compatible with the ADEMCO bi–directional devices.
Models 5802MN and 5804 have not been evaluated for use in UL installations.

Relay/Trigger Outputs

The system allows up to 22 programmable outputs. It provides 4 built-in triggers with the option of
adding up to four XL4705 Relay Modules (which provide up to 20 relay outputs). If the relay modules
are used, they must be enabled during programming (Submode 1, Question 12, Location 2). When using
relay modules, built-in triggers 3 and 4 no longer function as triggers but serve as clock and data inputs
for the modules. The remaining 2 built-in triggers provide a total of up to 22 programmable outputs.
See Programming Questions 32–43 in Submode 1 for individual trigger programming options.
Each XL4705 Relay Module provides five form C relays. Each module must be assigned a unique
module address (0–3) using its DIP switches. The module addresses allow the system to identify the
specific relay numbers being used according to the following table:
Built-in triggers 1–4 are programmed in Questions 42–43.
NOTE: If the system uses relay modules, only triggers 1 and 2 are available.
North America
Western Europe
(345MHz)
(433.92MHz)
5816
5816EU
5890/5890PI
5888EU
5802MN
5802EU
5808LST
5808EU
5804
5804EU
Module
Module DIP
Number
Address
1
0
2
1
3
2
4
3
Section 4. System Configuration
Outside Western
Europe (433.92MHz)
ZR510
ZR530
ZR520
N/A
ZR590
Relay
Program
Numbers
Question
1–5
Q32–34
6–10
Q34–36
11–15
Q37–Q39
16–20
Q39–Q41
Europe
(868MHz)
5816H
5888H
5802H
5808H
5804H
4–3