The System Wide Parameters include the software release, version number, the authorized number of ports,
and options. Starred (*) items require the system to be restarted before they take effect.
The first screen provides information only. It may be useful to you or may be needed during a technical support
call.
Screen Timeout This is the time before the administration screen will revert to the port status screen.
Daily Maintenance Time This is the time when SVM 400 performs routine daily maintenance. Daily mainte-
nance will save the system tables and perform message purging (Voice Mail or Announcement features). Inputs
must be specified in 24-hour time. The default setting is 3:00 a.m.
Maintenance will not occur until:
It is after the daily maintenance time, and
G
23 hours have elapsed since startup or the last daily maintenance interval.
G
Additionally the system will perform an orderly reset after approximately 240 days of operation right after daily
maintenance.
Subscriber Default Password The digits used as the default settings for extension and mailbox passwords.
The digit input may be from 1 to 8 digits. When a mailbox or extension password is reset, this is the value that
the password will be reset to. The default setting is 0000.
System Admin This effects both the GUI and the TUI. With the GUI; this password gives the administrator
access to all parameters. It is the highest level password and enables the administrator access to shutting the
system down. With the TUI: this password along with the remote login procedure gives the administrator
access to Recording System Prompts and Overriding the scheduling by engaging a specific mode.
Application Admin This works with the GUI only and denies access to only three areas: System Wide
Parameters, Exit SVM 400, and Port Activity. This is typically given out to an administrator's assistant. Though
accessing the system with this password could still allow the user to damage the application, they would not be
able to shut down the system or change the passwords.
Subscriber Admin This effects only the GUI and allows access only to the following: Subscriber List, Display
User Log, and Status Screen.
Min Recorded Length This parameter sets the minimum record time that is to be considered valid. It is speci-
fied in hundredths of seconds. A setting of 50 means 0.5 seconds or 500 milliseconds. The default value is 75.
If this value is too high, short recordings will be discarded. If it is too low, the system will consider disconnects
as a valid recording.