To Turn Off Gas To The Appliance; Operating Control - STA-RITE 200K BTU/HR Owner's Manual

Sr pool and spa heater natural gas / lp gas; 200k btu/hr; 333k btu/hr; 400k btu/hr
Hide thumbs Also See for 200K BTU/HR:
Table of Contents

Advertisement

6. Turn the knob on the gas control clockwise (
the black line, depress slightly, and turn to "OFF" posi-
tion. See Figure 4.
Gas control is shown OFF.
Turn Counter-clockwise
and release to turn gas on.
You are
here
2672 1096
FIGURE 4: Gas control in OFF position
7. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow "B" in the "Before Startup"
instructions (Page 4). If you don't smell gas, go to the
next step.
8. Turn the knob on the gas control counter-clockwise
(
) to the "ON" position. See Figure 5.
Gas control is shown ON.
Turn Clockwise and press
down to turn gas off.
You are
here
FIGURE 5: Gas control in "ON" position
9. Replace jacket cover(s). All jacket covers must be in
) to
place when operating the appliance.
10. Set 3-way valves on inlet and outlet to pool or spa, as
appropriate.
Indexing Poin
11. Turn on all electric power to the appliance.
12. Press either the POOL ON or SPA ON button switches
on the operating control.
13. Set the thermostat to desired setting (NOTICE: Set
point must be above actual water temperature or burn-
er will not fire.). See OPERATING CONTROL below.
14. The blower should come on immediately, and after
about 20 seconds, the burner should fire. When oper-
ating for the first time, the burner may not fire on the
first try because of air in the gas line. If it does not fire
at first, push the OFF switch, wait five minutes, and
again push the POOL or SPA ON switch. The burner
should fire after about 20 seconds. You may have to
repeat this until all of the air has cleared the gas line.
Gas is no
15. The burner should fire until the pool/spa temperature
reaches the desired temperature set on the thermostat.
The blower will continue to run for about 45 seconds
You are
after the burner shuts off. If any of the safety interlocks
should open during burner operation, the burner shuts
off immediately, but the blower continues to run for
about 45 seconds.
Should overheating occur or the gas supply fail to shut
off, turn off the manual gas control valve to the appli-
ance.
16. If the appliance will not operate, follow the instruc-
tions "TO TURN OFF GAS TO THE APPLIANCE", and
call your service technician or gas supplier.

TO TURN OFF GAS TO THE APPLIANCE

1. Depress OFF button on operating control.
Indexing Poin
2. Turn off all electric power to the unit.
3. Remove jacket cover(s). See Figure 3.
4. Turn the knob on the gas control clockwise (
the black line, depress slightly, and turn to "OFF" posi-
tion. See Figure 4.
5. Replace jacket cover(s).
Gas is no
You are
2671 10
6
HEATER PARTS MAY BE HOT.
) to

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents