Jet VBS-3612 Operating Instructions And Parts Manual page 27

36-inch metalworking band saw
Hide thumbs Also See for VBS-3612:
Table of Contents

Advertisement

Trouble
Machine will not
start/restart or
repeatedly trips
circuit breaker or
blows fuses.
Band Saw does not
come up to speed.
Probable Cause
Motor failure.
Miswiring of the unit.
Switch failure.
Extension cord too light or too long.
Low current.
Remedy
If electric motor is suspect, you have
two options: Have a qualified
electrician test the motor for function
or remove the motor and take it to a
qualified electric motor repair shop
and have it tested.
Double check to confirm all electrical
connections are correct. Refer to
appropriate wiring diagrams on pages
40 and 41 to make any needed
corrections.
If the start/stop switch is suspect, you
have two options: Have a qualified
electrician test the switch for function,
or purchase a new start/stop switch
and establish if that was the problem
on changeout.
Replace with adequate size and
length cord.
Contact a qualified electrician.
27