Astro Spectra Plus Vocon Dc Supply Failure - Motorola ASTRO Digital Spectra Service Manual

Uhf/vhf/800 mhz mobile radios
Hide thumbs Also See for ASTRO Digital Spectra:
Table of Contents

Advertisement

5-20
Check for 1.8V at R419
Make sure the following
components are placed
No
and soldered correctly:
Present?
U410, C430 R431, R451, R452,
C433, C415, R419
Yes
Check for 3.0 V at R420
Make sure the following
No
components are placed
Present?
and soldered correctly:
U411, C434, C435, C436, C437,
R420
Yes
Check for 13.8 V at J501-35
No
Inspect placement and
Present?
soldering of J501
Yes
No trouble found
Chart C.26 ASTRO Spectra Plus VOCON DC Supply Failure
July 1, 2002
Yes
OK?
Replace U410
No
Repair proper
components
Yes
OK?
Replace U411
No
Repair proper
components
Yes
Recycle radio
OK?
power
No
Repair connector
No
Refer board to
Fixed?
Service Depot
Yes
END
No
Refer board to
Fixed?
Service Depot
Yes
END
No
Refer board to
Fixed?
Service Depot
Yes
END
Troubleshooting Charts
68P81076C25-C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digital spectra plusAstro digital spectra plus

Table of Contents