Regardless of whether the VLAN 1 Conductor is inside or outside of the cluster, all
NIONS in the cluster that are in VLAN 2 will be getting their clock from XDAB and
cannot receive their clock from an outside Conductor. This would create a clocking
conflict.
Therefore, the Conductor for VLAN 2 must be located within the XDAB cluster, as
shown.
Scenario 7 - Network with VLAN and XDAB
This scenario is a variant of the previous scenario (on page 56).
The Conductor for VLAN1 is outside the XDAB cluster. This will still work.
The CobraNet interface in the XDAB master will sync to the Conductor outside the
cluster. That clock will become the XDAB master clock. XDAB and VLAN 1 will be in
sync.
However, the Conductor for VLAN 2 must still remain within the cluster because all
XDAB slaves in a cluster will receive their clock from XDAB and not from CobraNet.
Placement of VLAN 2's Conductor outside the cluster will cause the XDAB clock and
externally sourced VLAN 2 CobraNet clock to be in conflict.
Scenario 8 - Network with VLAN and two XDAB clusters
This scenario is a variant of the previous scenario (on page 57), but contains more than one
XDAB cluster.
June 11, 2012
Version 1.6.4b.1
NION Hardware Manual
57