FinePix30i(U/E/EG) SERVICE MANUAL
4-2-3.Jig Connection Diagram
FinePix30i
Digital Voltmeter
(note1)
(note1)Please sence input voltage at DC_IN terminal in case of System block adjustment.

4-2-4.Environmental Setting for adjustment

(1)Environmental Setting for Image System Adjustment(Fig.A)
<<Full White Pattern>>
Remove the chart from the pattern box. Position the
camera (lens surface when the power is on) and pattern
box so that they are separated by approximately 5 cm.
Arrange so that the standards for the pattern box are as
follows.
1. Brightness: 160+-5 cd/m
No chart – Center of pattern box.
Minolta luminous meter LS-110
2. Color warmth: 6100+-50
No chart – Center of pattern box.
Minolta colormeter F
(2)Environmental Setting for Flash Adjustment/
Inspection(Fig.B)
The strobe adjustment is easily affected by other
sources of light. Make the area around the gray chart
extremely dark to minimize the affects of other sources
of light.
Position 100 cm from the camera (lens surface).
Gray chart standards
Gray chart should be Superior Oxford Gray (No. 22) and
USB Terminal
DC_IN Terminal
2
(with LB140 filter)
o
K (with LB140 filter)
USB cable
Power Cable Jig
45+-5
camera
Body
10+-5
mm
100cm
camera
Body
Fig.B
4.Adjustment
Personal Computer
D C 5 V
Reguratted power supply
mm
Pattern
BOX
Filter(LB140)
Fig.A
Gray chart