Alarm
E69
Washing heating element interrupted (thermofuse open)
Faulty NTC sensor; Wiring faulty;
E71
PCB faulty.
E72
Wiring faulty; Drying NTC sensor (condenser) faulty; PCB faulty.
Wiring faulty; Drying NTC sensor (duct) faulty; PCB faulty.
E73
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty.
E74
E82
PCB faulty (Wrong configuration data). Selector, wiring
E83
PCB faulty (Wrong configuration data). Selector, wiring
Wiring faulty; Faulty control/display board
E91
PCB faulty.
Wrong control/display board;
E92
Wrong PCB (do not correspond to the model).
Incorrect configuration data; PCB faulty.
E93
E94
Incorrect configuration data; PCB faulty.
E95
PCB faulty.
E97
Faulty PCB (Wrong configuration data).
E98
Incompatibility between main board and Inverter.
E9b / E9H Display board.
E9C
Display board.
E9d
Display board.
E9F
PCB.
EH1
Power supply problems (incorrect / disturbance); PCB faulty.
EH2
Power supply problems (incorrect / disturbance); PCB faulty.
EH3
Power supply problems (incorrect / disturbance); PCB faulty.
EHE
Wiring faulty; PCB faulty.
EHF
PCB faulty.
EC1
Solenoid valve faulty/blocked; PCB faulty.
EC3
Wiring faulty; Weight sensor faulty; PCB faulty.
Ed1
Wiring faulty between PCB and WD board; WD board faulty; PCB faulty.
Ed2
Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty.
Ed3
Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty.
Ed4
Wiring faulty: WD board faulty; PCB faulty.
SOI/DT 2007-10 dmm
Possible fault
42/48
Action/machine status
----------------
Heating is skipped.
Drying heating is skipped
Drying heating is skipped
Heating is skipped.
----------------
Cycle cancelled.
----------------
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Wait for frequency nominal
conditions.
Wait for voltage nominal conditions.
Wait for voltage nominal conditions.
Safety drain cycle – Cycle stopped
with door open.
Safety drain cycle – Cycle stopped
with door open.
Cycle interrupted with door closed.
Drain pump functions always (5 min.,
then it stops for 5 min. etc.)
----------------
Cycle interrupted.
Cycle interrupted with door open.
Cycle interrupted with door open.
Cycle interrupted with door open.
Reset
START/RESET
START/RESET
START/RESET
START/RESET
START/RESET
RESET
START/RESET
RESET
OFF/ON START
OFF/ON
OFF/ON
RESET
RESET
OFF/ON
ON/OFF RESET
ON/OFF RESET
ON/OFF RESET
OFF/ON
OFF/ON
OFF/ON
OFF/ON
RESET
RESET
RESET
START/RESET
OFF/ON
RESET
RESET
RESET
599 70 27-90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents