Rapid Reading Of Alarm Codes; Cancelling The Last Alarm - Electrolux ENV06 Service Manual

Hide thumbs Also See for ENV06:
Table of Contents

Advertisement

6.3

Rapid reading of alarm codes

The last three alarm codes can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
→ Press and hold down START/PAUSE and the P5 button (as to enter the DIAGNOSTICS), for at least two
seconds: the display shows directly a screen with all the alarms.
→ To return to the main screen press any button.
→ The alarm reading system is as described in paragraph 5.2.
→ While the alarms are displayed, the appliance continues to perform the cycle or, if in the programme
selection phase, maintains the previously-selected options in memory.
6.4

Cancelling the last alarm

It is good practice to cancel the last alarm:
after reading the alarm code, to check whether the alarm re-occurs during diagnostics;
after repairing the appliance, to check whether it re-occurs during testing.
1. Select diagnostics mode and turn the programme selector to the tenth position (alarm
reading,; the CD display shows only the last alarm while pushing the TEMPERATURE
or SPIN button the history of the last three alarms is displayed).
2. Press the START/PAUSE and the P5 button simultaneously (as represented in
figure).
3. Hold down the buttons (at least 5 seconds) till the LCD display shows "E00" (for the first
displaying) "E00 E00 E00" for the second option.
N.B. With this operation all the memorised alarms are deleted.
SOI/DT 2007-10 dmm
21/48
599 70 27-90