Th-42Pd50U; Power Led Flashing Timing Chart - Panasonic TH-37PX50U Technical Manual

Hide thumbs Also See for TH-37PX50U:
Table of Contents

Advertisement

TH-42PD50U

Power LED Flashing timing chart

The unit is equipped with a self-protection circuit that places it in standby when there is
an abnormality with one or more of the Power Supply circuits. The faulty circuit may be
easily identified by counting the number of flashes emitted by the power LED located in
front of the unit.
Number of
Power LED
blinks
1
4
5
6
7
8
9
10
11
12
Blinking Timing
Table 6
53
Suspected Board
D, P board
P, PA board (Power
SOS)
D, P board (5V SOS)
SC board (SC E
nergy
recovery and
SC floating voltage)
SS Board (SS Data
Energy recovery and
data driver)
SS board (SS Energy
recovery)
Incorrect D, DG board
PA Board (No power
for tuner)
PB board, Fan (Fan
SOS)
H, PB, Z Board
(Sound SOS /
Speaker shorted)