Th-42/50Px500U; Power Led Flashing Timing Chart - Panasonic TH-37PX50U Technical Manual

Hide thumbs Also See for TH-37PX50U:
Table of Contents

Advertisement

TH-42/50PX500U

Power LED Flashing timing chart

The unit is equipped with a self-protection circuit that places it in standby when there is
an abnormality with one or more of the Power Supply circuits. The faulty circuit may be
easily identified by counting the number of flashes emitted by the power LED located in
front of the unit.
Number
of Power
LED
blinks
1
4
5
6
7
8
9
10
11
12
Note: LED indicators on the SS and SC boards alert the technician when a problem
exists. The LEDs should be lit during normal operation, a dark LED indicates that a
problem exists on that board.
Blinking Timing
Table 4
40
Suspected Board
D, P board
P, PA board (Power
SOS)
D, P board (5V SOS)
SC board (SC Energy
recovery and SC
floating voltage)
SS Board (SS Data
Energy recovery and
data driver)
SS board (SS Energy
recovery)
Incorrect D, DG board
PA Board (No power
for tuner)
PB board, Fan (Fan
SOS)
H, PB, Z Board
(Sound SOS / Speaker
shorted)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents